Permit Number - TC-RES-1222-01488
Permit Status: Inspections
Permit Description: SFR
Start Date Submittal Complete Date Status  
05/01/2023 RESIDENTIAL NEW DWELLING v.2 05/23/2023 REQUIRES RESUBMIT Review Details
01/19/2023 RESIDENTIAL NEW DWELLING v.1 02/14/2023 REQUIRES RESUBMIT Review Details
07/10/2023 RESIDENTIAL NEW DWELLING v.3 07/25/2023 APPROVED Review Details

Conditions

Permit Number - TC-RES-1222-01488
Permit Status: Inspections
Permit Description: SFR
Date Description Comments
07/25/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-1222-01488
Permite Description: SFR
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
12/06/2023 COT - RSBU - Excavation/Rebar/Zoning N/A Partial Pass Partial pass. Rebar in footings per plan. Pending #4 horizontal dowels every 32 o.c. Okay for concrete placement in footing. 12/6/2023
02/07/2024 COT - RSBU - Masonry Pregrout N/A Re-inspection required 1/23/24: vertical reinforcement is per plan #5 rebar at 32"O.C, horizontal reinforcement calls out for #5 rebar at 24"O.C per plan (8" reinforcement ladder mesh was installed) detail 6/A,

Not ready rebar not per plan. 1/29/2024
2/1/24 3rd lift ok for grout

1/30/24:vertical reinforcement is per plan #5 rebar at 32"O.C, horizontal reinforcement calls out for #5 rebar at 24"O.C per plan (8" reinforcement ladder mesh was installed) detail 6/A. Proceed at risk second lift ok to grout. Revision will need to be submitted prior to final inspection showing change in horizontal reinforcement.

2/7/24: reinforcement not per plan (rebar lap for #5 must be 30" and they must be spaced 32" o.c), plans call for 3 #5 continuous at top 4 courses not per plan, reinforcement not per plan.
06/07/2024 BULD - Electrical Clearance N/A Partial Pass Electric clearance for temporary construction power only.
06/28/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 6/28/24: corrections not made from previous inspection

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-1222-01488
Permit Description: SFR
Total Completed Inspections - 8
Date Description Inspector Results Comments
12/19/2023 COT - RSBU - Stem Wall/Retaining Wall Passed
01/02/2024 COT - RSPL - Rough Soil Passed
01/10/2024 COT - RSBU - Preslab Passed
02/09/2024 COT - RSBU - Masonry Pregrout Passed
03/01/2024 COT - RSBU - Roof Nailing Passed
07/23/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
03/20/2025 COT - BULD - SWG Clearance Passed Ok to set gas meter and start new service; Code: ECO
04/16/2025 RSBU - Building Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
OBA_V1.PDF DOCUMENTS VIEW
CONS-TC-RES-1220-01488_V3_V1.PDF DOCUMENTS VIEW
TC-RES-1220-01488_V3 MECHANICAL SUBMITTAL_V1.PDF DOCUMENTS VIEW
TC-RES-1220-01488_V3 STRUCTURAL CALCS_V1.PDF DOCUMENTS VIEW
DDO_23_12_DECISION.PDF SPECIAL APPLICATIONS VIEW
DDO_23_12_NOTICE.PDF SPECIAL APPLICATIONS VIEW
DDO_23_12_APPLICATION.PDF SPECIAL APPLICATIONS VIEW
DDO_23_12_PLAN SET.PDF SPECIAL APPLICATIONS VIEW