Permit: TC-RES-1222-01488

Parcel: 129051570


Addresses:

2026 E 17TH ST

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Masonry Pregrout 

Date Description Inspector Results Comments
01/23/2024 COT - RSBU - Masonry Pregrout  Re-inspection required 1/23/24: vertical reinforcement is per plan #5 rebar at 32"O.C, horizontal reinforcement calls out for #5 rebar at 24"O.C per plan (8" reinforcement ladder mesh was installed) detail 6/A,
01/29/2024 COT - RSBU - Masonry Pregrout  Re-inspection required Not ready rebar not per plan. 1/29/2024
01/30/2024 COT - RSBU - Masonry Pregrout  Partial Pass 1/23/24: vertical reinforcement is per plan #5 rebar at 32"O.C, horizontal reinforcement calls out for #5 rebar at 24"O.C per plan (8" reinforcement ladder mesh was installed) detail 6/A,

Not ready rebar not per plan. 1/29/2024

1/30/24:vertical reinforcement is per plan #5 rebar at 32"O.C, horizontal reinforcement calls out for #5 rebar at 24"O.C per plan (8" reinforcement ladder mesh was installed) detail 6/A. Proceed at risk second lift ok to grout. Revision will need to be submitted prior to final inspection showing change in horizontal reinforcement.
02/01/2024 COT - RSBU - Masonry Pregrout  Partial Pass
02/07/2024 COT - RSBU - Masonry Pregrout  Re-inspection required 1/23/24: vertical reinforcement is per plan #5 rebar at 32"O.C, horizontal reinforcement calls out for #5 rebar at 24"O.C per plan (8" reinforcement ladder mesh was installed) detail 6/A,

Not ready rebar not per plan. 1/29/2024
2/1/24 3rd lift ok for grout

1/30/24:vertical reinforcement is per plan #5 rebar at 32"O.C, horizontal reinforcement calls out for #5 rebar at 24"O.C per plan (8" reinforcement ladder mesh was installed) detail 6/A. Proceed at risk second lift ok to grout. Revision will need to be submitted prior to final inspection showing change in horizontal reinforcement.

2/7/24: reinforcement not per plan (rebar lap for #5 must be 30" and they must be spaced 32" o.c), plans call for 3 #5 continuous at top 4 courses not per plan, reinforcement not per plan.
02/09/2024 COT - RSBU - Masonry Pregrout  Passed