Permit: TC-RES-1222-01488

Parcel: 129051570


Addresses:

2026 E 17TH ST

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
06/27/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 6/27/24: metal boxes must be grounded, seal all penetrations through top plate, PVC to ABS not allowed with multi purpose adhesive, DWV not under test, ensure all grounds and neutrals are separated at sub-panel, Unit heater missing per plans, plumbing and electrical not roughed-in at kitchen sink, water supply line for fridge missing, receptacle missing at kitchen wall (spacing not per code), nail plates missing throughout, 1 1/4" VTR missing at laundry per plans, gas piping not properly secured not under test,
STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 6/28/24: corrections not made from previous inspection
07/16/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 6/27/24: metal boxes must be grounded, seal all penetrations through top plate, PVC to ABS not allowed with multi purpose adhesive, DWV not under test, ensure all grounds and neutrals are separated at sub-panel, Unit heater missing per plans, plumbing and electrical not roughed-in at kitchen sink, water supply line for fridge missing, receptacle missing at kitchen wall (spacing not per code), nail plates missing throughout, 1 1/4" VTR missing at laundry per plans, gas piping not properly secured not under test,
STOPPED INSPECTION MORE ITEMS MAY BE ADDED.

6/28/24: corrections not made from previous inspection

7/16/24: per previous notes
07/23/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed