Permit: TC-RES-1025-05316
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
1524 S SAINT TROPAZ PL
Address NEW:
1524 S SAINT TROPAZ PL
Apply Date:
10/31/2025
Applicant:
Luis Mireles
Description:
add a master bedroom/bath/w- closet and open patio
Permit Reviews
Permit Number - TC-RES-1025-05316
Permit Status: Inspections complete
Permit Description: add a master bedroom/bath/w- closet
and open patio
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/18/2025 | ADMINISTRATIVE v.2 | 12/18/2025 | APPROVED |
| 12/05/2025 | ADMINISTRATIVE v.1 | 12/05/2025 | REQUIRES RESUBMIT |
| 11/06/2025 | RESIDENTIAL ADD/ALT v.1 | 12/05/2025 | APPROVED |
Conditions
Permit Number - TC-RES-1025-05316
Permit Status: Inspections complete
Permit Description: add a master bedroom/bath/w- closet
and open patio
| Date | Description | Comments |
|---|---|---|
| 11/06/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-1025-05316
Permite Description: add a master bedroom/bath/w- closet
and open patio
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required (with fee) | 2-20-26: footer at patio (detail 2) does not meet depth requirements. Remove rock/boulder at column footer and remove excess concrete from footer at the southwest end of new addition so that it meets depth requirements as outlined per detail 1. Missing #4 dowels at 32" o.c.-dowels must be installed at the existing concrete-see foundation plan for information. Also, underground plumbing/DWV cannot be installed directly in footings nor was the DWV not completely wrapped-consult with an architect to provide details on how to correct. |
| 02/20/2026 | RSPL - Plumbing Progress | N/A | Re-inspection required | 2-20-26: footer at patio (detail 2) does not meet depth requirements. Remove rock/boulder at column footer and remove excess concrete from footer at the southwest end of new addition so that it meets depth requirements as outlined per detail 1. Missing #4 dowels at 32" o.c.-dowels must be installed at the existing concrete-see foundation plan for information. Also, underground plumbing/DWV cannot be installed directly in footings nor was the DWV not completely wrapped-consult with an architect to provide details on how to correct. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-1025-05316
Permit Description: add a master bedroom/bath/w- closet
and open patio
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Ok to place concrete in footings and slab areas. | |
| 04/14/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 4/14/26 corrections made | |
| 04/23/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | All corrections were made. 4/23/2026 | |
| 04/23/2026 | COT - RSPL - Rough Soil | Passed | Approved per JIM B. 4/23/2026 | |
| 04/23/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 04/23/2026 | COT - RSBU - Preslab | Passed | ||
| 05/29/2026 | RSBU - Building Final | Passed | ||
| 05/29/2026 | RSBU - Building Progress | Passed | ||
| 05/29/2026 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 05/29/2026 | COT - RSEL - Electrical Final | Passed | 05/29/2026 Verified added AFCI type breaker at main panel to service bedroom circuit. |
|
| 05/29/2026 | RSEL - Electrical Progress | Passed | ||
| 05/29/2026 | RSPL - Plumbing Progress | Passed | ||
| 05/29/2026 | COT - RSPL - Plumbing Final | Passed | 05/29/2026 Verified shutoff and p-trap installed properly at bathroom sink. |
|
| 05/29/2026 | COT - RSME - Mechanical Final | Passed |