Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/20/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Provide a 6/12 nailing pattern at osb. Ledger at patio needs to be nailed off. Provide caps at beams to post. Provide 2xs at ends both patio and closet location along with straps to beam. Loose anchor bolts throughout. Provide pins at closet bottom plate. Add mechanical fasteners to rafters south end. Provide ladder for roof inspection. 3/20/2026 | |
| 04/08/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 4.8.26 Some items from previous notes remain Plans call for Simpson bc6 at post to beam Anchor bolts still loose Add nails to missing runs/over penetrated runs at roof sheathing |
|