Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
03/20/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Provide a 6/12 nailing pattern at osb. Ledger at patio needs to be nailed off. Provide caps at beams to post. Provide 2xs at ends both patio and closet location along with straps to beam. Loose anchor bolts throughout. Provide pins at closet bottom plate. Add mechanical fasteners to rafters south end. Provide ladder for roof inspection. 3/20/2026
04/08/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 4.8.26
Some items from previous notes remain
Plans call for Simpson bc6 at post to beam
Anchor bolts still loose
Add nails to missing runs/over penetrated runs at roof sheathing
04/14/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 4/14/26 corrections made