Permit: TC-RES-1025-05260
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
237 W OHIO ST UNIT 1
Address NEW:
237 W OHIO ST UNIT 1
Apply Date:
10/28/2025
Applicant:
armando olvera
Description:
Duplex - replaces SFR - TC-DMO-1025-00217
Permit Reviews
Permit Number - TC-RES-1025-05260
Permit Status: Inspections
Permit Description: Duplex - replaces SFR - TC-DMO-1025-00217
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/18/2026 | RESIDENTIAL NEW DWELLING v.2 | 03/05/2026 | REQUIRES RESUBMIT |
| 11/03/2025 | RESIDENTIAL NEW DWELLING v.1 | 11/13/2025 | REQUIRES RESUBMIT |
| 03/11/2026 | RESIDENTIAL NEW DWELLING v.3 | 03/13/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-1025-05260
Permit Status: Inspections
Permit Description: Duplex - replaces SFR - TC-DMO-1025-00217
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 11/04/2025 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 11/04/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-1025-05260
Permit Status: Inspections
Permit Description: Duplex - replaces SFR - TC-DMO-1025-00217
| Date | Description | Comments |
|---|---|---|
| 11/03/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 11/03/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-1025-05260
Permite Description: Duplex - replaces SFR - TC-DMO-1025-00217
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 05/08/2026 Unit 1 Add blocking on three sides to air registers throughout, add FHA nail with 8 nails in each side to reinforce top plate splice in laundry area, sub panel in currently in the laundry closet - needs to moved, brace air duct in living. Unit 2 Add blocking on three sides to air registers throughout, add fire foam to top plate penetration in bedroom as marked, add FHA nail with 8 nails in one side to reinforce top plate splice in laundry area, add stud shoe to over-notched stud in bathroom and backing on walls, add Boca plate at kitchen sink. |
| 05/08/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Partial Pass | 05/08/2026 Corrections made to 4/22/26 inspection. Partial pass pending architect revision and letter. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-1025-05260
Permit Description: Duplex - replaces SFR - TC-DMO-1025-00217
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2026 | COT - RSPL - Rough Soil | Passed | 3-23-26: underground plumbing verified per plans-okay to backfill using shading materials. | |
| 03/26/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 03/26/2026 | COT - RSBU - Preslab | Passed | ||
| 04/16/2026 | COT - RSBU - Firewall/Fire Barrier/Firestop | Passed | 04/16/2026 Verified final firewall 5/8" type-x gypsum. No penetrations, added seal on edges. |
|
| 04/22/2026 | COT - RSBU - Roof Nailing | Passed | 4-22-26: okay to dry-in at own risk (pending exterior clips/framing RFI). | |
| 05/08/2026 | BULD - Electrical Clearance | Passed | 05/08/2026 Clearance TEP ECO. Duplex Unit 1 & Unit 2. |
|
| 05/15/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 05/15/2026 All corrections made to prior inspection. Added bracing to vent thru roof pipes in both units. |
|
| 06/10/2026 | COT - RSBU - Interior Shear Bracing | Passed |