Permit: TC-RES-1025-05260

Parcel: 120082930

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
05/08/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 05/08/2026
Unit 1
Add blocking on three sides to air registers throughout, add FHA nail with 8 nails in each side to reinforce top plate splice in laundry area, sub panel in currently in the laundry closet - needs to moved, brace air duct in living.

Unit 2
Add blocking on three sides to air registers throughout, add fire foam to top plate penetration in bedroom as marked, add FHA nail with 8 nails in one side to reinforce top plate splice in laundry area, add stud shoe to over-notched stud in bathroom and backing on walls, add Boca plate at kitchen sink.
05/15/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 05/15/2026
All corrections made to prior inspection. Added bracing to vent thru roof pipes in both units.