Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/22/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 4-22-26: add shot pins to marked locations. A minimum of 2 shot pins are required per plate. Add nails to sheathing at marked locations. Add anchor bolts to marked location. Missing ADA backing at restrooms-See plans for details/requirements. Have architect submit a revision addressing the porch glulam beam & cutting of 4x8 post on interior side of home, a revision addressing gable end bracing with hardware is required for porches gable end bracing on interior side. Any beam to post will require cs straps- please address this too. | |
| 05/08/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 05/08/2026 Corrections made to 4/22/26 inspection. Partial pass pending architect revision and letter. |
|
| 05/21/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 5-21-26: verified wall post& glulam beam connection detail #4 which was submitted as a revision to the city, however, revision has not yet been approved. It is okay to continue with construction but will be at own risk. This inspection will be closed out after or if plan review gets approved. |