Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Apply Date:
09/09/2025
Applicant:
Jason Ayler
Description:
Convert Detached Building into ADU with Bathroom Addition

Permit Reviews

Permit Number - TC-RES-0925-04449
Permit Status: Inspections
Permit Description: Convert Detached Building into ADU with Bathroom Addition
Start Date Submittal Complete Date Status  
01/02/2026 RESIDENTIAL ADU v.4 01/15/2026 REQUIRES RESUBMIT Review Details
09/12/2025 RESIDENTIAL ADU v.1 10/16/2025 REQUIRES RESUBMIT Review Details
05/14/2026 ADMINISTRATIVE v.1 N/A REQUIRES RESUBMIT Review Details
11/24/2025 RESIDENTIAL ADU v.2 12/05/2025 REQUIRES RESUBMIT Review Details
02/13/2026 RESIDENTIAL ADU v.5 02/13/2026 REQUIRES RESUBMIT Review Details
02/20/2026 RESIDENTIAL ADU v.6 03/13/2026 REQUIRES RESUBMIT Review Details
12/22/2025 RESIDENTIAL ADU v.3 12/22/2025 REQUIRES RESUBMIT Review Details
05/04/2026 RESIDENTIAL ADU v.7 N/A APPROVED Review Details

Conditions

Permit Number - TC-RES-0925-04449
Permit Status: Inspections
Permit Description: Convert Detached Building into ADU with Bathroom Addition
Date Description Comments
09/12/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0925-04449
Permite Description: Convert Detached Building into ADU with Bathroom Addition
Total Outstanding Inspections - 11
Last Inspection Date Description Inspector Results Comments
07/02/2026 COT - RSBU - Excavation/Rebar/Zoning N/A Not Applicable
07/02/2026 RSBU - Building Final N/A Re-inspection required 7.2.26
1. Subpanel needs minimum of 36" clearance in front
2. Need 2 small appliance circuit in kitchen on 20A breakers GFCI protected
3. Bathroom receptacles need to be GFCI protected
4. Mini Split is not UL listed.
5. Water heater needs t/p line terminating to a pan or ground 2"-6".
6. Label all circuits and create panel schedule.
7. Water hammer arrestors needed at laundry washer.
07/02/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Not Applicable
07/02/2026 COT - RSBU - Preslab N/A Not Applicable
07/02/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Applicable
07/02/2026 COT - RSBU - Roof Nailing N/A Not Applicable
07/02/2026 COT - RSEL - Electrical Final N/A Re-inspection required 7.2.26
1. Subpanel needs minimum of 36" clearance in front
2. Need 2 small appliance circuit in kitchen on 20A breakers GFCI protected
3. Bathroom receptacles need to be GFCI protected
4. Mini Split is not UL listed.
5. Water heater needs t/p line terminating to a pan or ground 2"-6".
6. Label all circuits and create panel schedule.
07/02/2026 COT - RSME - Mechanical Final N/A Re-inspection required 7.2.26
1. Subpanel needs minimum of 36" clearance in front
2. Need 2 small appliance circuit in kitchen on 20A breakers GFCI protected
3. Bathroom receptacles need to be GFCI protected
4. Mini Split is not UL listed.
5. Water heater needs t/p line terminating to a pan or ground 2"-6".
6. Label all circuits and create panel schedule.
7. Water hammer arrestors needed at laundry washer.
07/02/2026 COT - RSPL - Yard Water Line N/A Not Applicable
07/02/2026 COT - RSPL - Plumbing Final N/A Re-inspection required 7.2.26
1. Subpanel needs minimum of 36" clearance in front
2. Need 2 small appliance circuit in kitchen on 20A breakers GFCI protected
3. Bathroom receptacles need to be GFCI protected
4. Mini Split is not UL listed.
5. Water heater needs t/p line terminating to a pan or ground 2"-6".
6. Label all circuits and create panel schedule.
7. Water hammer arrestors needed at laundry washer.
07/02/2026 COT - RSPL - Rough Soil N/A Not Applicable

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-5672 E ALTA VISTA_PLAN_SET_042926_V2.PDF DOCUMENTS VIEW
DDO-26-14 DECISION TP_MOD_1025_000072_V2.PDF DOCUMENTS VIEW