Permit Number: TC-RES-0925-04449
Parcel: 110150290

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.2

Permit Number - TC-RES-0925-04449
Review Name: RESIDENTIAL ADU v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/05/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/24/2025 Addressing Validation REQUIRES RESUBMIT There appears to be two units linked to this address. An address change request must be completed through the sub record of this permit to add correct unit number to this permit. Once that request is submitted, please resubmit construction documents to reflect the updated address with unit number. Instructions can be found here to request change of address: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf
For questions: PDSD-Residential@tucsonaz.gov
12/03/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0925-04449 2nd
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings.

Provide a response letter addressing each comment with location of change on the plans.

Remove the photos into a separate file from the construction plans. The photos may be useful during inspection.

Submit separate letter and plan set files.

SITE PLAN:

1. Show the location of the water and electrical service, R106.1.1. Each dwelling requires an appropriate source of electrical and water supply. Show the location and size of lines with connection points, R106.1.1. Identify the utility lines requiring upgrade or replacement.
2. Show the patio cover on the site plan. Clarify if is included with this building alteration or was built with a previous permit.

PLANS:

1. Provide a Roof Framing Plan and detail showing the patio cover rafters with direct connection to the load bearing wall, R106.1.1. Bolded fastening to the building overhang requires a registered engineer’s stamp for a performance solution.

ELECTRICAL PLANS:

1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; circuits #11 and 13, E3703.2 and E3901.3.
2. The pool pump circuit #4 may not be used in the building.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
12/05/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston, Planner

PROJECT: TC-RES-0925-04449
5672 E Alta Vista St., Tucson, AZ 85712
ADU (2nd Review)

TRANSMITTAL DATE: 12/05/2025

This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. Per UDC Table 6.3-2.A, the front yard perimeter setback for the R-1 zone is 20’, not 30’as shown on the site plan. Please correct the site plan, and Sheet A1 which lists the property designation being RH with a front setback of 50’ and the side and rear being 10’.

2. The wording for the side and rear setbacks are listed, but the 6’ measurement is not indicated. Correct the site plan.

3. Requirements for what needs to be listed on the site plan can be found at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example Add an engineer scale to the site plan (no need for the site map and image). For example, 1” = 10’.

4. The Pima County’s Assessor’s Office lists Somkit Thoummany as the property owner of record. Add the owner’s name and address to the site plan or provide evidence that this is no longer the owner.

5. Now that confirmation has been provided by Pima County for the addressing, label the primary residence Unit 1 and the proposed ADU as Unit 2 on the site plan. The address should now read ‘5672 E Alta Vista St., Unit 2, Tucson, AZ 85712.’

6. While the northern lot line dimension of 111.11’has been corrected per Comment 4 of the Zoning Review dated 10/16/25, the eastern lot line measures 156.03’ per the 1956 Carlos Terrace subdivision plat as and not 158.03’as shown on the site plan. Please correct the site plan.

7. Recalculate the total lot coverage by adding the square footage of the existing residence (2,578 sq. ft.), the ADU (377 sq. ft.) and the square footage of the vehicle use areas (1,865 sq. ft.). These total 4,820 sq. ft. Porches are not included in the lot coverage calculation. Divide this 4,820 by the total lot area (15,044 sq. ft.) to arrive at the total lot coverage – approx. 32%.


8. Comment 5 of the Zoning Review dated 10/16/25 states that a DDO application is necessary for the approval of a reduced rear setback, less than the 5’ required for ADUs. As shown on the site plan and explained in the Response Letter provided for this review, the ADU perimeter setback is 1’from the property line which triggers a DDO, even though the porch was existing because the addition of the ADU constitutes a change of use. Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf . For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov

9. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
11/24/2025 PDSD Application Completeness Express REVIEW COMPLETED