Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADU v.1
Permit Number - TC-RES-0925-04449
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/19/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 10/16/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/12/2025 | Addressing Validation | REQUIRES RESUBMIT | ATTENTION: Parcel/addressing issue. The site plan shows to be for an ADU(Accessory Dwelling Unit). The location does not have units attached to the address and does not appear to be associated with a parcel. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and add the units. After address/units have been added or verified you'll need to submit an address change request in this permit's sub records to update this record along with a new aerial/site plan that shows the corrected addressing. For questions: Building_Official@tucsonaz.gov |
||
| 10/06/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0925-04449 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. SITE PLAN: 1. Show the location of the water and electrical service, R106.1.1. Each dwelling requires an appropriate source of electrical and water supply. Show the location and size of lines with connection points, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. Show the patio cover on the site plan. Clarify if is included with this building alteration or was built with a previous permit. PLANS: 1. Provide a Roof Framing Plan showing the ridge beam and rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) including the patio cover if constructed with the bathroom addition. SECTIONS - DETAILS: 1. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-30 for an addition not greater than 500 SF. PLUMBING PLANS: 1. Show an individual accessible water supply shut off and water heater for the proposed dwelling unit, P2903.9.1. 2. Show the water heater rating, P2801.1. MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Identify the device model number providing an adjustable setting and note the minimum continuous setting. A one-bedroom dwelling under 1501 SF requires a 30 CFM continuous setting. ELECTRICAL PLANS: 1. Show a smoke alarm in the bedroom area with an electrical circuit, R314. 2. Provide a minimum service conductor rating of #3 copper 75 degree C for the 100 AMP feeder, E3602.1 & E3603.1. Update the riser diagram. 3. Show the bathroom receptacle with a separate 20 AMP circuit, E3703.4 and E3901.6. 4. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. OUTDOOR LIGHTING CODE 1. Remove the flood and spot lamp note as this is not part of the lighting code, OLC 401.3. Adjustable aim fixtures are unshielded. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 10/16/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-0925-04449 5672 E ALTA VISTA ST Convert Detached Building into ADU with Bathroom Addition (1st Review) TRANSMITTAL DATE: 10/16/25 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. Comment 1: Please include vehicular use area in lot coverage and update calculations. Comment 2: Please draw and dimension the front setback measurement between the front of the main home and front property line. Comment 3: Please draw, dimension, and label the wall height of the proposed ADU from design grade to the top of the exterior walls on at least one of the elevation drawings. Comment 4: According to the Pima County Subdivision Plat Map, the north property line is 111.11’. Please correct this measurement on the site plan. The plat map may be found here: https://www.asr.pima.gov/ParcelData/Map/Arm/MP12/M12012.PDF Comment 5: Please draw and label the setback between one of the back porch posts on the proposed ADU and the rear property line. Conversion of the existing detached accessory structure to an ADU constitutes a change of use. Full code compliance is required. If the setback is 1’ or greater, a Design Development Option (DDO) will be needed for the approval of a reduced setback (less than the required 5’ for ADUs). Please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf. For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov Comment 6: Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials. Comment 7: Some of the measurements on the site plan appear inaccurate based on the provided scale. Please ensure the scale and all measurements on the site plan are correct. Comment 8: Please include the zoning designation of the surrounding properties, which are R-1 to the north, south, and west, and R-2 to the east. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 09/12/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |