Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
4757 S GOLDENROD PL
Apply Date:
07/22/2024
Applicant:
Gary Olsen
Description:
Fire Damage Repair

Permit Reviews

Permit Number - TC-RES-0724-04251
Permit Status: Complete
Permit Description: Fire Damage Repair
Start Date Submittal Complete Date Status  
07/23/2024 RESIDENTIAL NEW DWELLING v.1 08/22/2024 APPROVED Review Details

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0724-04251
Permite Description: Fire Damage Repair
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
10/21/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 10-21-24, DWV not under test and approved stamped plans were not on site. Customer asked to reschedule when ready.
12/16/2024 COT - RSEL - Electrical Final N/A Canceled Cancelled by Gary Olsen. Wanted residential intermediate inspection.
06/30/2025 COT - RSEL - Outdoor Lighting N/A Re-inspection required House being epoxied, no access
12/16/2024 COT - RSME - Mechanical Final N/A Canceled Cancelled by Gary Olsen. Wanted residential intermediate inspection.
06/27/2025 COT - RSPL - Plumbing Final N/A Re-inspection required 6/27/25
1. Water hammer arrestor needed for dishwasher, dishwasher not secured
2. GFCI circuit in kitchen not working
3. Garbage disposal/dishwasher receptacle not working
4. Bedroom 3: receptacles have open hot.
5. Bedroom 2: smoke detector needs to be minimum 3 ft from supply register.
6. Thermostat too high, no higher than 48".
7. Laundry receptacle needs to be GFCI protected.
8. Need condensate line for hvac, and must be painted.
9. Run t/p to safer location.
10. Need Carbon Monoxide detector.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0724-04251
Permit Description: Fire Damage Repair
Total Completed Inspections - 10
Date Description Inspector Results Comments
12/16/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 12/16/24: Gas line is under 15 psi of air pressure with no leaks. Electrical has been properly installed through roof for a/c unit. Okay to proceed with other work.
12/16/2024 COT - RSPL - Gas Pressure Test Passed Gas line is under 15 psi of air pressure with no leaks. Okay to proceed with other work.
02/07/2025 COT - BULD - SWG Clearance Passed Gas valve is installed in kitchen for stove. Okay to reconnect gas meter 12414948
02/07/2025 BULD - Electrical Clearance Passed 2/7/25: Electrical panel is complete, wiring is connected to breakers, all receptacles and switches are installed with cover plates installed. Okay to reconnect electrical meter #165 020 155
02/07/2025 COT - RSBU - Roof Nailing Passed
07/15/2025 RSBU - Building Final Passed 7/15/25 passed
07/15/2025 COT - RSEL - Electrical Final Passed 7/15/25 passed
07/15/2025 COT - RSEL - Outdoor Lighting Passed 7/15/25 passed
07/15/2025 COT - RSME - Mechanical Final Passed 7/15/25 passed
07/15/2025 COT - RSPL - Plumbing Final Passed 7/15/25 passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-GOLDENROD PLACE COMBINED_V1.PDF DOCUMENTS VIEW