Permit: TC-RES-0724-04251
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
4757 S GOLDENROD PL
Address NEW:
4757 S GOLDENROD PL
Apply Date:
07/22/2024
Applicant:
Gary Olsen
Description:
Fire Damage Repair
Permit Reviews
Permit Number - TC-RES-0724-04251
Permit Status: Complete
Permit Description: Fire Damage Repair
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/23/2024 | RESIDENTIAL NEW DWELLING v.1 | 08/22/2024 | APPROVED |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0724-04251
Permite Description: Fire Damage Repair
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 10-21-24, DWV not under test and approved stamped plans were not on site. Customer asked to reschedule when ready. |
| 12/16/2024 | COT - RSEL - Electrical Final | N/A | Canceled | Cancelled by Gary Olsen. Wanted residential intermediate inspection. |
| 06/30/2025 | COT - RSEL - Outdoor Lighting | N/A | Re-inspection required | House being epoxied, no access |
| 12/16/2024 | COT - RSME - Mechanical Final | N/A | Canceled | Cancelled by Gary Olsen. Wanted residential intermediate inspection. |
| 06/27/2025 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 6/27/25 1. Water hammer arrestor needed for dishwasher, dishwasher not secured 2. GFCI circuit in kitchen not working 3. Garbage disposal/dishwasher receptacle not working 4. Bedroom 3: receptacles have open hot. 5. Bedroom 2: smoke detector needs to be minimum 3 ft from supply register. 6. Thermostat too high, no higher than 48". 7. Laundry receptacle needs to be GFCI protected. 8. Need condensate line for hvac, and must be painted. 9. Run t/p to safer location. 10. Need Carbon Monoxide detector. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0724-04251
Permit Description: Fire Damage Repair
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 12/16/24: Gas line is under 15 psi of air pressure with no leaks. Electrical has been properly installed through roof for a/c unit. Okay to proceed with other work. | |
| 12/16/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line is under 15 psi of air pressure with no leaks. Okay to proceed with other work. | |
| 02/07/2025 | COT - BULD - SWG Clearance | Passed | Gas valve is installed in kitchen for stove. Okay to reconnect gas meter 12414948 | |
| 02/07/2025 | BULD - Electrical Clearance | Passed | 2/7/25: Electrical panel is complete, wiring is connected to breakers, all receptacles and switches are installed with cover plates installed. Okay to reconnect electrical meter #165 020 155 | |
| 02/07/2025 | COT - RSBU - Roof Nailing | Passed | ||
| 07/15/2025 | RSBU - Building Final | Passed | 7/15/25 passed | |
| 07/15/2025 | COT - RSEL - Electrical Final | Passed | 7/15/25 passed | |
| 07/15/2025 | COT - RSEL - Outdoor Lighting | Passed | 7/15/25 passed | |
| 07/15/2025 | COT - RSME - Mechanical Final | Passed | 7/15/25 passed | |
| 07/15/2025 | COT - RSPL - Plumbing Final | Passed | 7/15/25 passed |