Permit: TC-RES-0724-04251

Parcel: 136382310


Addresses:

4757 S GOLDENROD PL

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Final 

Date Description Inspector Results Comments
06/27/2025 COT - RSEL - Electrical Final  Re-inspection required 6/27/25
1. Water hammer arrestor needed for dishwasher, dishwasher not secured
2. GFCI circuit in kitchen not working
3. Garbage disposal/dishwasher receptacle not working
4. Bedroom 3: receptacles have open hot.
5. Bedroom 2: smoke detector needs to be minimum 3 ft from supply register.
6. Thermostat too high, no higher than 48".
7. Laundry receptacle needs to be GFCI protected.
8. Need condensate line for hvac, and must be painted.
9. Run t/p to safer location.
10. Need Carbon Monoxide detector.
07/15/2025 COT - RSEL - Electrical Final  Passed 7/15/25 passed
12/16/2024 COT - RSEL - Electrical Final  Canceled Cancelled by Gary Olsen. Wanted residential intermediate inspection.