Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address NEW:
326 E DISTRICT ST
Apply Date:
06/01/2024
Applicant:
Inai Maldonado
Description:
SFR

Permit Reviews

Permit Number - TC-RES-0624-03324
Permit Status: Inspections complete
Permit Description: SFR
Start Date Submittal Complete Date Status  
10/31/2024 RESIDENTIAL NEW DWELLING v.3 12/12/2024 APPROVED Review Details
06/03/2024 RESIDENTIAL NEW DWELLING v.1 07/01/2024 REQUIRES RESUBMIT Review Details
12/12/2024 RESTAMP - RESIDENTIAL v.1 12/12/2024 APPROVED Review Details
05/23/2025 RESIDENTIAL NEW DWELLING v.1 05/26/2025 APPROVED Review Details
09/30/2024 RESIDENTIAL NEW DWELLING v.2 10/22/2024 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0624-03324
Permit Status: Inspections complete
Permit Description: SFR
Total Outstanding Activity Conditions - 1
Date Name
12/12/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/

Conditions

Permit Number - TC-RES-0624-03324
Permit Status: Inspections complete
Permit Description: SFR
Date Description Comments
06/18/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
06/18/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0624-03324
Permite Description: SFR
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
05/28/2025 COT - RSME - Mechanical Final N/A Re-inspection required 5-28-25, missing cooktop and anti tip device, missing address identification sign on residence, cut cleanouts to grade, gas meter must be installed, hammer arrestors required at washer/dryer, 90 degree elbows required on exterior plastic, paint all exterior pvc, insulate copper hose bib and wrap with 10 mil tap, 2 clamps are required for electrical risers, vacuum breakers required on hose bibs, gfci receptacles are required on kitchen and bathrooms, a ledger board with a future light box was installed on home and is not per approved plans-submit an RFI or remove altogether, provide plans to verify thermostat height. If home was designed as an inclusive home then height shall be at 42" o.c...
05/28/2025 COT - RSPL - Plumbing Final N/A Re-inspection required 5-28-25, missing cooktop and anti tip device, missing address identification sign on residence, cut cleanouts to grade, gas meter must be installed, hammer arrestors required at washer/dryer, 90 degree elbows required on exterior plastic, paint all exterior pvc, insulate copper hose bib and wrap with 10 mil tap, 2 clamps are required for electrical risers, vacuum breakers required on hose bibs, gfci receptacles are required on kitchen and bathrooms, a ledger board with a future light box was installed on home and is not per approved plans-submit an RFI or remove altogether, provide plans to verify thermostat height. If home was designed as an inclusive home then height shall be at 42" o.c...
05/28/2025 COT - RSEL - Electrical Final N/A Re-inspection required 5-28-25, missing cooktop and anti tip device, missing address identification sign on residence, cut cleanouts to grade, gas meter must be installed, hammer arrestors required at washer/dryer, 90 degree elbows required on exterior plastic, paint all exterior pvc, insulate copper hose bib and wrap with 10 mil tap, 2 clamps are required for electrical risers, vacuum breakers required on hose bibs, gfci receptacles are required on kitchen and bathrooms, a ledger board with a future light box was installed on home and is not per approved plans-submit an RFI or remove altogether, provide plans to verify thermostat height. If home was designed as an inclusive home then height shall be at 42" o.c...

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0624-03324
Permit Description: SFR
Total Completed Inspections - 16
Date Description Inspector Results Comments
12/24/2024 COT - RSPL - Rough Soil Passed 12/24/24 pass
12/24/2024 COT - RSBU - Preslab Passed 12/24/24 pass
02/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Corrections made while on site, ok to proceed to intermediate stage
02/10/2025 COT - RSBU - Roof Nailing Passed Corrections made while on site, ok to proceed to intermediate stage
03/19/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 19 March 25
Pass, okay to proceed with insulation and drywall.
04/10/2025 COT - RSEL - Grounding/Bonding Passed
04/09/2025 BULD - Electrical Clearance Passed 4/9/25: INCR TEP CLEARANCE FOR 326 E DISTRICT ST
05/28/2025 COT - RSPL - Yard Water Line Passed 5-28-25, previously inspected.
05/28/2025 COT - RSEL - Outdoor Lighting Passed 5-28-25, approved
05/28/2025 COT - RSPL - Sewer Passed 5-28-25, previously inspected.
05/28/2025 COT - RSPL - Gas Pressure Test Passed 5-28-25, approved
05/28/2025 COT - RSBU - Excavation/Rebar/Zoning Passed 5-28-25, previously inspected.
05/30/2025 COT - RSME - Mechanical Final Passed
05/30/2025 RSBU - Building Final Passed
05/30/2025 COT - RSPL - Plumbing Final Passed
05/30/2025 COT - RSEL - Electrical Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-2_PLAN_SET_V3.PDF DOCUMENTS VIEW