Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0624-03324
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/01/2024 | Site Engineering | NOT REQUIRED | |||
| 07/01/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/18/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0624-03324 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: Provide a response letter on separate file with submitting the updated construction plan set. GENERAL COMMENTS : 1. All plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Show a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain when the clothes washer is not located at an exterior wall. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations PLUMBING PLANS: 1. Show the gray water loop extended from a tub and remove the diverter valve. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations 2. Remove the septic note and replace with HCS at the building drain for consistency with the site plan, R106.1.1. MECHANICAL PLANS: 1. Show the minimum whole-house airflow rate setting and location of the device requiring this adjustable setting, M1505.4. A two- or three-bedroom dwelling greater than 1501 SF requires a 60 CFM continuous setting. ELECTRICAL PLANS: 1. Clothes Washer and Dishwasher GFCI: receptacles require readily accessible protection typically from an upstream device, E3902.9 & 10. Add notation to plans or panel schedule. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 06/21/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0624-03324 326 East District Street – R-2 New single-family residence (1st Review) TRANSMITTAL DATE: June 21, 2024 1. A front perimeter fence appears in aerial imagery in 2014. A zoning compliance review was not obtained for this fence. Indicate the location and maximum height of the perimeter fence on the site plan. Additionally, provide a dimension from the centerline of District Street to the face of curb location, as well as a dimension from the face of curb location to the street property line, to ensure the fence is within the property boundaries. Per sheet ten of paving plan I-780, the distance from the centerline of District Street to the face of curb location is 18 feet, and the distance from the face of curb location to the street property line is 12 feet: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-780. 2. Clarify whether the existing single-family residence is proposed for demolition. A separate demolition permit will be required. According to the Pima County Assessor’s Office, the effective date of construction of the building is 1952. As the building is 50 years of age or older, architectural documentation is required to be submitted with the demolition permit prior to Zoning approval. The architectural documentation requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/historic_demolition_application_form.pdf. 3. Perimeter yards are based on a measurement from the design grade elevation to the highest point of an exterior building wall (see UDC 6.4.5.B and Figure 6.4.5-A). Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required perimeter yard is 6’-0” or 2/3 the height of the exterior building wall, whichever is greater. Based on a wall height of 9’-6”, the required side perimeter yard is 6’-4” as measured from the east lot line. The proposed side perimeter yard is 6’-0”. A Design Development Option (DDO) is required to reduce the above requirement. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Contact Georgia.Pennington@tucsonaz.gov or Mark.Castro@tucsonaz.gov if you have questions about the DDO process. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 06/03/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |