Permit: TC-RES-0424-02593
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
902 W PENNSYLVANIA ST
Address NEW:
902 W PENNSYLVANIA ST
Apply Date:
04/29/2024
Applicant:
Oscar Juarez
Description:
SFR at parcel 2 of subdivided Plat
Permit Reviews
Permit Number - TC-RES-0424-02593
Permit Status: Complete
Permit Description: SFR at parcel 2 of subdivided Plat
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/30/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/04/2024 | APPROVED |
| 06/12/2024 | RESIDENTIAL NEW DWELLING v.2 | 06/24/2024 | APPROVED |
| 05/01/2024 | RESIDENTIAL NEW DWELLING v.1 | 05/30/2024 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0424-02593
Permit Status: Complete
Permit Description: SFR at parcel 2 of subdivided Plat
| Date | Description | Comments |
|---|---|---|
| 05/15/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 05/15/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0424-02593
Permite Description: SFR at parcel 2 of subdivided Plat
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2024 | COT - RSPL - Rough Soil | N/A | Re-inspection required | 8/20/24: pipes must be (burped) in order to release all trapped air from system and have all fittings tested under 5' of pressure above highest fitting. 1" pex must be pressurized prior to backfill. Shading material required. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0424-02593
Permit Description: SFR at parcel 2 of subdivided Plat
Total Completed Inspections - 15
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2024 | COT - RSPL - Rough Soil | Passed | 8/20/24: pipes must be (burped) in order to release all trapped air from system and have all fittings tested under 5' of pressure above highest fitting. 1" pex must be pressurized prior to backfill. Shading material required. 8/21/24: corrections made ok to proceed with backfill. Shading required |
|
| 08/21/2024 | COT - RSPL - Yard Water Line | Passed | 8/21/24: 1" pex ran from future location of meter to P.O.C at home. Ok to backfill progress area. | |
| 08/28/2024 | COT - RSBU - Preslab | Passed | 8/27/24: #4 rebar requires 24" of overlap at splices, 3" of clearance required around reinforcement, wrap all plumbing pipes that will be encased in concrete, footings must be 12" below grade, clear all footings of debris. 8/28/24: passed. |
|
| 09/11/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 09/11/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 09/13/2024 | COT - RSBU - Roof Nailing | Passed | ||
| 09/13/2024 | BULD - Electrical Clearance | Passed | 9/11/24: Temp GFCI must be installed for clearance. Address tag required for clearance 9/13/24: ECO TEP Clearance For 902 W PENNSYLVANIA ST |
|
| 09/13/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 09/24/2024 | COT - RSPL - Sewer | Passed | ||
| 10/01/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Ok to insulate and cover walls. | |
| 11/21/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
| 11/21/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 11/21/2024 | COT - RSEL - Electrical Final | Passed | ||
| 11/21/2024 | COT - RSME - Mechanical Final | Passed | ||
| 11/21/2024 | RSBU - Building Final | Passed |