Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Preslab  

Date Description Inspector Results Comments
08/27/2024 COT - RSBU - Preslab   Re-inspection required 8/27/24: #4 rebar requires 24" of overlap at splices, 3" of clearance required around reinforcement, wrap all plumbing pipes that will be encased in concrete, footings must be 12" below grade, clear all footings of debris, front porch forms not per plan
08/28/2024 COT - RSBU - Preslab   Passed 8/27/24: #4 rebar requires 24" of overlap at splices, 3" of clearance required around reinforcement, wrap all plumbing pipes that will be encased in concrete, footings must be 12" below grade, clear all footings of debris.
8/28/24: passed.