Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Rough Soil 

Date Description Inspector Results Comments
08/20/2024 COT - RSPL - Rough Soil  Re-inspection required 8/20/24: pipes must be (burped) in order to release all trapped air from system and have all fittings tested under 5' of pressure above highest fitting. 1" pex must be pressurized prior to backfill. Shading material required.
08/21/2024 COT - RSPL - Rough Soil  Passed 8/20/24: pipes must be (burped) in order to release all trapped air from system and have all fittings tested under 5' of pressure above highest fitting. 1" pex must be pressurized prior to backfill. Shading material required.
8/21/24: corrections made ok to proceed with backfill. Shading required