Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
533 W DAKOTA ST
Address NEW:
533 W DAKOTA ST
Apply Date:
02/11/2025
Applicant:
Jackquelin Guerrero
Description:
REV_1, Change fastening details; SFR

Permit Reviews

Permit Number - TC-RES-0225-00785
Permit Status: Inspections
Permit Description: REV_1, Change fastening details; SFR
Start Date Submittal Complete Date Status  
12/22/2025 RESIDENTIAL NEW DWELLING REVISION v.1 01/06/2026 APPROVED Review Details
04/25/2025 RESIDENTIAL NEW DWELLING v.2 05/20/2025 REQUIRES RESUBMIT Review Details
11/03/2025 RESIDENTIAL NEW DWELLING REVISION v.1 11/13/2025 REQUIRES RESUBMIT Review Details
12/03/2025 RESTAMP - RESIDENTIAL v.1 12/04/2025 APPROVED Review Details
02/24/2025 RESIDENTIAL NEW DWELLING v.1 03/31/2025 REQUIRES RESUBMIT Review Details
07/29/2025 RESTAMP - RESIDENTIAL v.1 07/30/2025 APPROVED Review Details
07/02/2025 RESIDENTIAL NEW DWELLING v.3 07/29/2025 APPROVED Review Details
10/27/2026 BUILDING DEFERRED SUBMITTAL REVIEW v.1 10/27/2026 APPROVED Review Details
12/01/2025 RESIDENTIAL NEW DWELLING REVISION v.2 12/02/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-0225-00785
Permit Status: Inspections
Permit Description: REV_1, Change fastening details; SFR
Date Description Comments
02/24/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
02/24/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
03/20/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
03/20/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0225-00785
Permite Description: REV_1, Change fastening details; SFR
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
11/10/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Ready Not ready. Ensure lath is in place. Ensure roof is dry in and roof tile is loaded prior to intermediate. Ensure clip nail inspection is closed out before intermediate. 11/10/2025
10/27/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 10-27-25: add an anchor to marked location at garage-anchor bolts are required within 12" at the end of each plate. Add shot pin within 6" at the end of plate and space 24" o.c., nailing for exterior not per plan-add nails along edges/joints no closer than 3/8" from joints and 12" o.c. In the field. Add nails to sheathing where nails over penetrate more than 1/8". Missing A35's and H25's at ledger at back exit to patio, add 2x6 blocking at 6' apart for gable end truss, add anchor bolts to all sides of columns and add studs per plans, missing Simpson nail plates to top plates at 48" o.c.-see plans for details.STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE ADDED.
05/28/2026 COT - RSPL - Plumbing Final N/A Not Ready 5/28/2026
Not ready.
10/20/2026 RSBU - Building Final N/A Partial Pass 10/20/2026
Partial pass pending sewer and truss conditions need to be satisfied.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0225-00785
Permit Description: REV_1, Change fastening details; SFR
Total Completed Inspections - 16
Date Description Inspector Results Comments
09/09/2025 COT - RSPL - Sewer Passed 9-9-25: sewer connection approved. Okay to backfill with shading materials.
09/09/2025 COT - RSPL - Rough Soil Passed 9-9-25: underground plumbing approved. Okay to backfill with shading materials.
12/30/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
12/30/2025 BULD - Electrical Clearance Passed 12/30/25: ECO TEP CLEARANCE APPROVED
12/30/2025 COT - RSBU - Preslab Passed
01/08/2026 COT - RSBU - Interior Shear Bracing Passed 1-8-26: interior shear bracing approved-okay to tape & texture drywall.
04/28/2026 COT - RSPL - Yard Water Line Passed
05/28/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 5/28/2026
Passed on prior inspections, verified corrections made.
05/28/2026 COT - RSEL - Grounding/Bonding Passed 5/28/2026
Passed on prior inspections 12/30/25.
05/28/2026 COT - RSBU - Excavation/Rebar/Zoning Passed 5/28/2026
Passed on prior inspections for foundation and footings, customer uncertain if needed inspection for driveway and rear patio slab.
05/28/2026 COT - RSBU - Roof Nailing Passed 5/28/2026
Approved.
10/20/2026 COT - RSEL - Electrical Final Passed
10/20/2026 COT - RSPL - Plumbing Final Passed 10/20/2026
Painted plastic pipes outdoors.
10/20/2026 COT - RSEL - Outdoor Lighting Passed
10/20/2026 COT - RSME - Mechanical Final Passed
10/21/2026 RSBU - Building Final Passed 10/21/2026
Conditions satisfied. Uploaded truss design and sewer permit, see attachments.

Documents

File Name Document Type  
TRUSS-N1_V1.PDF DOCUMENTS VIEW
WATERRECEIPT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
RESPONSE LETTET TC-RES-0225-00785 (REV-4)_V1.PDF DOCUMENTS VIEW
REV4_PLAN SET MR - MRS ROLANDO GUERRERO 1 TC-RES-0225-00785_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-REV2_PLAN SET MR - MRS ROLANDO GUERRERO 1 TC-RES-0225-00785 (6) NEW_V3.PDF DOCUMENTS VIEW
REV3_PLAN SET MR - MRS ROLANDO GUERRERO 1 TC-RES-0225-00785_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
OBA 533 W DAKOTA_V1.PDF DOCUMENTS VIEW
CONS-REV2_PLAN SET MR - MRS ROLANDO GUERRERO 1 TC-RES-0225-00785 (6) NEW_V3.PDF DOCUMENTS VIEW