| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/20/2025 | Residential Building - Standard | APPROVED | |||
| 03/28/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 03/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/24/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: TC-RES-0225-00785 533 W Dakota St Tucson, AZ 85706 SFR (1st Review) TRANSMITTAL DATE: 3/24/2025 Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. This site is located in the O-3 zone (UDC 4.7.16). A single-family residence is a permitted use in this zone (Table 4.8-3) subject to Use Specific Standards 4.9.7.B.5 - .9. 1. Comment: The ½ Right of Way dimension provided on your site plan is incorrect. Per Maps and Records Paving Improvement Plan I-67-029, the ½ ROW should be 25’ (17’ from centerline to face of curb, 8’ from face of curb to the property line) https://maps-and-records.tucsonaz.gov/construction-plans/details/I-67-029. 2. Comment: The zoning to the west of the project is listed as O-3 however it is zoned C-2. The zoning to the south of the project is listed as C-2 however it is zoned R-2. The zoning across the street is listed as C-2 however it is zoned O-3. The zoning of this project is listed as C-2 in the lot coverage calculations however it is zoned O-3. Please update accordingly. 3. Comment: Site zoning is unable to approve the building permit until the Design Development Option (DDO) has been approved. Please see below. 4. Comment: The following comments are related to an application for a Design Development Option (DDO) (UDC 3.11.1): Per UDC Table 6.3-3.A, the minimum setback for residential use to a residential or nonresidential zone in the O-3 zone is the greater of 10’ or ¾ (Height) of the building exterior wall. Based on a proposed wall height of 9’ 8”, the required perimeter yard setback to the east property line is 10’. The proposed setback to the east property line is 8’. A DDO application must be submitted and approved to reduce the required perimeter yard setback. Please reach out to Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Mark Castro at Mark.Castro@tucsonaz.gov if needed. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 02/24/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |