Permit Number: TC-RES-0225-00785
Parcel: 137060550

Address:
533 W DAKOTA ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0225-00785
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/20/2025 Residential Building - Standard APPROVED
03/28/2025 Site Engineering - Standard NOT REQUIRED
03/28/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/24/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
PDSD Zoning Review Section

PROJECT: TC-RES-0225-00785
533 W Dakota St Tucson, AZ 85706
SFR (1st Review)

TRANSMITTAL DATE: 3/24/2025

Comment: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

This site is located in the O-3 zone (UDC 4.7.16). A single-family residence is a permitted use in this zone (Table 4.8-3) subject to Use Specific Standards 4.9.7.B.5 - .9.

1. Comment: The ½ Right of Way dimension provided on your site plan is incorrect. Per Maps and Records Paving Improvement Plan I-67-029, the ½ ROW should be 25’ (17’ from centerline to face of curb, 8’ from face of curb to the property line) https://maps-and-records.tucsonaz.gov/construction-plans/details/I-67-029.
2. Comment: The zoning to the west of the project is listed as O-3 however it is zoned C-2. The zoning to the south of the project is listed as C-2 however it is zoned R-2. The zoning across the street is listed as C-2 however it is zoned O-3. The zoning of this project is listed as C-2 in the lot coverage calculations however it is zoned O-3. Please update accordingly.
3. Comment: Site zoning is unable to approve the building permit until the Design Development Option (DDO) has been approved. Please see below.
4. Comment: The following comments are related to an application for a Design Development Option (DDO) (UDC 3.11.1):

Per UDC Table 6.3-3.A, the minimum setback for residential use to a residential or nonresidential zone in the O-3 zone is the greater of 10’ or ¾ (Height) of the building exterior wall. Based on a proposed wall height of 9’ 8”, the required perimeter yard setback to the east property line is 10’. The proposed setback to the east property line is 8’. A DDO application must be submitted and approved to reduce the required perimeter yard setback. Please reach out to Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Mark Castro at Mark.Castro@tucsonaz.gov if needed. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
02/24/2025 PDSD Application Completeness Express REVIEW COMPLETED