Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address NEW:
6802 S MISSIONDALE RD
Apply Date:
02/02/2024
Applicant:
Gilberto Gamboa
Description:
SFR

Permit Reviews

Permit Number - TC-RES-0224-00619
Permit Status: Inspections complete
Permit Description: SFR
Start Date Submittal Complete Date Status  
02/06/2024 RESIDENTIAL NEW DWELLING v.1 02/29/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0224-00619
Permit Status: Inspections complete
Permit Description: SFR
Total Outstanding Activity Conditions - 1
Date Name
02/14/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-0224-00619
Permit Status: Inspections complete
Permit Description: SFR
Date Description Comments
03/05/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
02/14/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0224-00619
Permite Description: SFR
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
04/26/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 4/25/24: anchor bolt spacing greater than 48" O.C at bedroom one south wall, Gable ends not per plan.
05/07/2024 COT - RSPL - Yard Water Line N/A Not Ready 5/7/24: not ready
05/06/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Ready
10/07/2024 COT - RSEL - Electrical Underground N/A Canceled 10/4/24: canceled by contractor no access
10/07/2024 COT - RSEL - Outdoor Lighting N/A Canceled 10/4/24: canceled by contractor no access
10/07/2024 COT - RSEL - Electrical Final N/A Canceled 10/4/24: canceled by contractor no access
10/07/2024 COT - RSME - Mechanical Final N/A Canceled 10/4/24: canceled by contractor no access
10/07/2024 COT - RSPL - Plumbing Final N/A Canceled 10/4/24: canceled by contractor no access
10/07/2024 RSBU - Building Final N/A Canceled 10/4/24: canceled by contractor no access

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0224-00619
Permit Description: SFR
Total Completed Inspections - 15
Date Description Inspector Results Comments
04/04/2024 COT - RSPL - Rough Soil Passed 4/1/24: Underground plumbing not under test.
4/3/24: underground plumbing not per plans missing gray water discharge
4/4/24: corrections made ok to backfill. Shading required
04/05/2024 COT - RSEL - Grounding/Bonding Passed 4/5/24: passed.
04/05/2024 COT - RSBU - Excavation/Rebar/Zoning Passed 4/3/24: canceled per Memo
4/5/24: passed ok to pour
04/05/2024 COT - RSBU - Preslab Passed 4/3/24: canceled per Memo
4/5/24: passed ok to pour
04/25/2024 COT - RSBU - Roof Nailing Passed
05/16/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 4/25/24: anchor bolt spacing greater than 48" O.C at bedroom one south wall, Gable ends not per plan. Back porch pending
5/6/24 cancel by contractor
5/16/24L corrections made.
05/16/2024 COT - RSPL - Yard Water Line Passed 5/7/24: not ready
5/16/24: passed ok to backfill. Shading required.
05/16/2024 COT - RSPL - Sewer Passed 5/7/24: not ready
5/16/24: passed, ok backfill. Shading required
05/16/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 5/6/24 cancel by contractor
5/16/24: passed. Ok to proceed
08/30/2024 BULD - Electrical Clearance Passed Approved new 200A service panel - ECO Clearance to TEP is required for the new service
10/08/2024 COT - RSEL - Outdoor Lighting Passed
10/08/2024 COT - RSEL - Electrical Final Passed
10/08/2024 COT - RSME - Mechanical Final Passed Canceled per contractor. 9/19/2024
10/4/24: canceled by contractor no access
10/8/24: condensate drain requires 90degree and must terminate 6" above grade, insulation required at exterior hose bib, clean outs must be capped and cut to grade. UV coat exterior plastic piping.
10/8/24: corrections made ok for CofO
10/08/2024 COT - RSPL - Plumbing Final Passed Canceled per contractor. 9/19/2024
10/4/24: canceled by contractor no access
10/8/24: condensate drain requires 90degree and must terminate 6" above grade, insulation required at exterior hose bib, clean outs must be capped and cut to grade. UV coat exterior plastic piping.
10/8/24: corrections made ok for CofO
10/08/2024 RSBU - Building Final Passed Canceled per contractor. 9/19/2024
10/4/24: canceled by contractor no access
10/8/24: condensate drain requires 90degree and must terminate 6" above grade, insulation required at exterior hose bib, clean outs must be capped and cut to grade. UV coat exterior plastic piping.
10/8/24: corrections made.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
SEWERCONNECTIONPERMIT_20240323_125523_V1.PDF DOCUMENTS VIEW
MISSIONDELE OWNER LETTER_V1.PDF DOCUMENTS VIEW