Permit: TC-RES-0126-00429
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
3042 S TOWER RD
Address NEW:
3042 S TOWER RD
Apply Date:
01/27/2026
Applicant:
Fernando Hinojosa
Description:
New Detached sleeping quarters.
Permit Reviews
Permit Number - TC-RES-0126-00429
Permit Status: Inspections
Permit Description: New Detached sleeping quarters.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/31/2026 | ADMINISTRATIVE v.1 | N/A | REQUIRES RESUBMIT |
| 03/16/2026 | RESIDENTIAL ADD/ALT v.2 | 03/31/2026 | APPROVED |
| 02/03/2026 | RESIDENTIAL ADD/ALT v.1 | 02/20/2026 | REQUIRES RESUBMIT |
| 03/31/2026 | ADMINISTRATIVE v.2 | N/A | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-0126-00429
Permit Status: Inspections
Permit Description: New Detached sleeping quarters.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/17/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-0126-00429
Permit Status: Inspections
Permit Description: New Detached sleeping quarters.
| Date | Description | Comments |
|---|---|---|
| 02/03/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0126-00429
Permite Description: New Detached sleeping quarters.
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/22/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 5-22-26: This job relates to a Code Enforcement Case/ Building without permits-provide truss calculations, add anchor bolts are marked locations, tighten all anchor bolts, anchor bolts are required within 12" at the end each exterior plate and 2 anchor bolts are required within 12" on each side of a splice, add shot pins to marked locations, provide a letter from a licensed contractor documenting exterior sheathing together with roof nailing was done per plans & meets the 2024 IRC-submit letter to the city as an attachment for review & approval, missing backing at the restroom. See the City of Tucson Inclusive page for bracing/backing requirements & add backing at restroom. Stopped inspection-additional items may be added. |
| 05/22/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 5-22-26: provide any pictures/videos which documents reinforcement, an X-Ray of reinforcement under the slab must be completed by a company who specializes in this field. Those reports must be submitted to the city for review/approval & expose pockets throughout exterior footings to verify depth. |
| 05/22/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 5-22-26: This job relates to a Code Enforcement Case/ Building without permits-provide truss calculations, add anchor bolts are marked locations, tighten all anchor bolts, anchor bolts are required within 12" at the end each exterior plate and 2 anchor bolts are required within 12" on each side of a splice, add shot pins to marked locations, provide a letter from a licensed contractor documenting exterior sheathing together with roof nailing was done per plans & meets the 2024 IRC-submit letter to the city as an attachment for review & approval, missing backing at the restroom. See the City of Tucson Inclusive page for bracing/backing requirements & add backing at restroom. Stopped inspection-additional items may be added. |
| 05/22/2026 | COT - RSPL - Sewer | N/A | Re-inspection required | 5-22-26: expose pockets throughout exterior underground plumbing to verify piping, tracer wire, excavation depth. For all underground plumbing underneath slab a snake with camera will be required to verify proper flow and contains no blockages. A certified licensed plumber is required to perform test. Provide all results/ reports upon re-inspection and upload them to the city for review. Expose sewer for same. All underground plumbing together with sewer requires a pressure test. |
| 05/22/2026 | COT - RSPL - Yard Water Line | N/A | Re-inspection required | 5-22-26: expose underground water line so that we may verify proper depth, tracer wire, proper installation, and water line must be tested under pressure. |
| 05/22/2026 | COT - RSPL - Rough Soil | N/A | Re-inspection required | 5-22-26: expose pockets throughout exterior underground plumbing to verify piping, tracer wire, excavation depth. For all underground plumbing underneath slab a snake with camera will be required to verify proper flow and contains no blockages. A certified licensed plumber is required to perform test. Provide all results/ reports upon re-inspection and upload them to the city for review. Expose sewer for same. All underground plumbing together with sewer requires a pressure test. |