Permit: TC-RES-0126-00429
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
3042 S TOWER RD
Address NEW:
3042 S TOWER RD
Apply Date:
01/27/2026
Applicant:
Fernando Hinojosa
Description:
New Detached sleeping quarters.
Permit Reviews
Permit Number - TC-RES-0126-00429
Permit Status: Inspections
Permit Description: New Detached sleeping quarters.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/31/2026 | ADMINISTRATIVE v.1 | N/A | REQUIRES RESUBMIT |
| 03/16/2026 | RESIDENTIAL ADD/ALT v.2 | 03/31/2026 | APPROVED |
| 02/03/2026 | RESIDENTIAL ADD/ALT v.1 | 02/20/2026 | REQUIRES RESUBMIT |
| 03/31/2026 | ADMINISTRATIVE v.2 | N/A | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-RES-0126-00429
Permit Status: Inspections
Permit Description: New Detached sleeping quarters.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/17/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-RES-0126-00429
Permit Status: Inspections
Permit Description: New Detached sleeping quarters.
| Date | Description | Comments |
|---|---|---|
| 02/03/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0126-00429
Permite Description: New Detached sleeping quarters.
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2026 | COT - RSPL - Rough Soil | N/A | Re-inspection required | 7/17/26: Sewer line is running parallel to footing within the 45 degree bearing plane. Rough soil will need to be re-done and have approved fittings and have appropriate slope for discharge. Areas that were not exposed will need to be snaked with cameras verify slope and fitting directions, multiple fittings in wall not installed in correct position. Boca plates required throughout where plumbing/mechanical/electrical come within 1 1/4" from face of stud. All penetrations at top plate must be properly sealed, over notched studs must be addressed, over notched top plates must be addressed, properly support DWV in wall and above ceiling, properly support pex lines, fully expose sewer connection outside of home, permit required for laundry room sewer run |
| 05/22/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 5-22-26: This job relates to a Code Enforcement Case/ Building without permits-provide truss calculations, add anchor bolts are marked locations, tighten all anchor bolts, anchor bolts are required within 12" at the end each exterior plate and 2 anchor bolts are required within 12" on each side of a splice, add shot pins to marked locations, provide a letter from a licensed contractor documenting exterior sheathing together with roof nailing was done per plans & meets the 2024 IRC-submit letter to the city as an attachment for review & approval, missing backing at the restroom. See the City of Tucson Inclusive page for bracing/backing requirements & add backing at restroom. Stopped inspection-additional items may be added. |
| 05/22/2026 | COT - RSPL - Yard Water Line | N/A | Re-inspection required | 5-22-26: expose underground water line so that we may verify proper depth, tracer wire, proper installation, and water line must be tested under pressure. |
| 05/22/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 5-22-26: This job relates to a Code Enforcement Case/ Building without permits-provide truss calculations, add anchor bolts are marked locations, tighten all anchor bolts, anchor bolts are required within 12" at the end each exterior plate and 2 anchor bolts are required within 12" on each side of a splice, add shot pins to marked locations, provide a letter from a licensed contractor documenting exterior sheathing together with roof nailing was done per plans & meets the 2024 IRC-submit letter to the city as an attachment for review & approval, missing backing at the restroom. See the City of Tucson Inclusive page for bracing/backing requirements & add backing at restroom. Stopped inspection-additional items may be added. |
| 05/22/2026 | COT - RSPL - Sewer | N/A | Re-inspection required | 5-22-26: expose pockets throughout exterior underground plumbing to verify piping, tracer wire, excavation depth. For all underground plumbing underneath slab a snake with camera will be required to verify proper flow and contains no blockages. A certified licensed plumber is required to perform test. Provide all results/ reports upon re-inspection and upload them to the city for review. Expose sewer for same. All underground plumbing together with sewer requires a pressure test. |
| 05/22/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 5-22-26: provide any pictures/videos which documents reinforcement, an X-Ray of reinforcement under the slab must be completed by a company who specializes in this field. Those reports must be submitted to the city for review/approval & expose pockets throughout exterior footings to verify depth. |
| 10/14/2026 | COT - RSBU - Interior Shear Bracing | N/A | Partial Pass | Partial pass. Drywall shall reach the bottom plate and fastened. Drywall screws shall not be closer to the edges of a minimum of 3/8". Ensure all boxes are cut out. 10/14/2026 |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0126-00429
Permit Description: New Detached sleeping quarters.
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2026 | COT - RSPL - Rough Soil | Passed | 7/30/26: Plumbing underground approved. Please ensure Preslab inspection is called in for pour backs at sawcut locations. | |
| 09/29/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 09/29/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 09/29/2026 | COT - RSPL - Yard Water Line | Passed | ||
| 09/29/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 09/29/2026 | COT - RSPL - Sewer | Passed | ||
| 09/29/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 10/15/2026 | COT - RSBU - Interior Shear Bracing | Passed |