Permit: TC-RES-0126-00429

Parcel: 119221040


Addresses:

3042 S TOWER RD

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Sewer 

Date Description Inspector Results Comments
05/22/2026 COT - RSPL - Sewer  Re-inspection required 5-22-26: expose pockets throughout exterior underground plumbing to verify piping, tracer wire, excavation depth. For all underground plumbing underneath slab a snake with camera will be required to verify proper flow and contains no blockages. A certified licensed plumber is required to perform test. Provide all results/ reports upon re-inspection and upload them to the city for review. Expose sewer for same. All underground plumbing together with sewer requires a pressure test.