Permit Reviews

Permit Number - TC-RES-0123-02498
Permit Status: Complete
Permit Description: Duplex
Start Date Submittal Complete Date Status  
10/31/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.2 11/05/2024 REQUIRES RESUBMIT Review Details
12/14/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 02/03/2025 APPROVED Review Details
02/03/2025 RESIDENTIAL NEW DWELLING REVISION v.1 03/07/2025 REQUIRES RESUBMIT Review Details
05/04/2023 RESTAMP - RESIDENTIAL v.1 05/04/2023 APPROVED Review Details
09/18/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/18/2024 REQUIRES RESUBMIT Review Details
04/06/2023 RESIDENTIAL NEW DWELLING v.2 05/04/2023 APPROVED Review Details
03/01/2023 RESIDENTIAL NEW DWELLING v.1 03/30/2023 REQUIRES RESUBMIT Review Details
04/02/2025 RESIDENTIAL NEW DWELLING REVISION v.2 04/29/2025 APPROVED Review Details
04/29/2025 RESTAMP - RESIDENTIAL v.1 04/30/2025 APPROVED Review Details
11/08/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.3 11/12/2024 APPROVED Review Details

Conditions

Permit Number - TC-RES-0123-02498
Permit Status: Complete
Permit Description: Duplex
Date Description Comments
11/08/2024 Compaction AND FILLING IS REQUIRED.
05/04/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.
11/08/2024 Architect submitted 11/8/24
11/08/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
08/19/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0123-02498
Permite Description: Duplex
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
12/17/2024 COT - RSEL - Grounding/Bonding N/A Partial Pass 12-17-24, partial pass for UFER.
12/17/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Partial Pass 12-17-24, carport still pending. Unit 1 clips/sheathing approved-Okay to continue construction.Unit 2, add shot pins to marked locations and an anchor bolt on west side.Reinspection required.
06/17/2025 COT - BULD - SWG Clearance N/A Not Applicable
12/30/2024 BULD - Electrical Clearance N/A Not Ready 12/30/24: Hold on Permit must be addressed prior to any further inspection being called in.
12/17/2024 COT - RSBU - Excavation/Rebar/Zoning N/A Partial Pass 10/15/24: reinforcement per plans at slab for home and patio ok to proceed. Pending car port.
11/27/24: Anchor bolts required to be 1/2" in size (currently installed are 3/8"), anchor bolts required 48" o.c at fire wall, anchor bolts required 12" from edge of sill plate, hold downs missing per plans at south west corner of duplex at unit 1, fire block required at west and east wall of fire wall, no roof access, please provide truss clacs, 3-10D nails required at ledger every stud, truss cannot be closer then 3" from splice of top plate,
06/18/2025 COT - RSEL - Outdoor Lighting N/A Re-inspection required 6-18-25: paint all exterior plastic including any plastic on rooftops, seal both water closets, lower thermostat height to 48" o.c., install light bulb on exterior light fixture. Unit 2-install anti-tip device at stove, lower thermostat to 48" o.c., paintball exterior plastic, seal both water closets, insulate copper hose bibs, and wrap using 10 mil tape, provide an updated panel schedule for unit 2-showing disposal.

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0123-02498
Permit Description: Duplex
Total Completed Inspections - 19
Date Description Inspector Results Comments
10/15/2024 COT - RSBU - Preslab and floodplain Passed
10/15/2024 COT - RSPL - Rough Soil Passed
12/17/2024 COT - RSBU - Roof Nailing Passed 12-17-24, roof nailing for units 1 & 2 approved. Okay to continue construction on roof.
02/05/2025 COT - RSPL - Gas Pressure Test Passed 2/5/25 pass
03/11/2025 COT - RSPL - Sewer Passed OK to,cover progress area.
06/17/2025 COT - RSEL - Grounding/Bonding Passed
06/17/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
06/17/2025 COT - RSBU - Interior Shear Bracing Passed
06/17/2025 COT - RSEL - Electrical Underground Passed
06/17/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
06/17/2025 BULD - Electrical Clearance Passed
06/17/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
06/17/2025 COT - RSBU - Firewall/Fire Barrier/Firestop Passed
06/17/2025 COT - RSPL - Yard Water Line Passed 6/17/2025 okay to backfill. Shading is required.
06/20/2025 COT - RSEL - Electrical Final Passed
06/20/2025 COT - RSME - Mechanical Final Passed 6/20/25
Pass
06/20/2025 COT - RSPL - Plumbing Final Passed 6/20/25
Pass
06/20/2025 RSBU - Building Final Passed 6/20/25
Pass
06/24/2025 COT - RSEL - Outdoor Lighting Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
4_A-1 THRU E-1 729 E 35TH DUPLEX PLANS OWNER REVISION _12-18-24_D2_REV1_V2.PDF DOCUMENTS VIEW
FINAL 729.PDF DOCUMENTS VIEW
2413246A.MMDL - PLAN -_V1.PDF DOCUMENTS VIEW
R85126418.2413246-A_V1.PDF DOCUMENTS VIEW
35 ST DUPLEX RESCHECK_V1_V2_V3.PDF DOCUMENTS VIEW
IN ACCORDANCE WITH A.R.C TITLE 32_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
2_A-1 THRU E-1 729 E 35TH DUPLEX PLANS_04-04-23_D1_V1.PDF DOCUMENTS VIEW
22365 MJ 729_V1.PDF DOCUMENTS VIEW