Permit: TC-RES-0123-02386
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
3145 W MOCKINGBIRD LN
Address NEW:
3145 W MOCKINGBIRD LN
Apply Date:
01/26/2023
Applicant:
JOSEPH TORRES
Description:
SFR
Permit Reviews
Permit Number - TC-RES-0123-02386
Permit Status: Inspections complete
Permit Description: SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/27/2024 | RESIDENTIAL NEW DWELLING v.1 | 07/02/2024 | APPROVED |
| 07/23/2024 | RESIDENTIAL NEW DWELLING v.1 | 07/23/2024 | REQUIRES RESUBMIT |
| 05/23/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 05/27/2025 | APPROVED |
| 05/22/2023 | RESIDENTIAL NEW DWELLING v.2 | 05/26/2023 | REQUIRES RESUBMIT |
| 03/01/2023 | RESIDENTIAL NEW DWELLING v.1 | 03/29/2023 | REQUIRES RESUBMIT |
| 07/18/2023 | RESTAMP - RESIDENTIAL v.1 | 07/19/2023 | APPROVED |
| 07/07/2023 | RESIDENTIAL NEW DWELLING v.4 | 07/18/2023 | APPROVED |
| 04/08/2025 | RESIDENTIAL NEW DWELLING REVISION v.1 | 05/06/2025 | APPROVED |
| 05/24/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 05/24/2024 | APPROVED |
| 08/09/2024 | RESIDENTIAL NEW DWELLING v.3 | 08/09/2024 | REQUIRES RESUBMIT |
| 08/15/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/19/2024 | APPROVED |
| 06/08/2023 | RESIDENTIAL NEW DWELLING v.3 | 07/07/2023 | REQUIRES RESUBMIT |
| 07/24/2024 | RESIDENTIAL NEW DWELLING v.2 | 07/24/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-0123-02386
Permit Status: Inspections complete
Permit Description: SFR
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 08/19/2024 | Missing Hillside Landscape Notes |
| 08/19/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
Conditions
Permit Number - TC-RES-0123-02386
Permit Status: Inspections complete
Permit Description: SFR
| Date | Description | Comments |
|---|---|---|
| 07/19/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit. | |
| 08/19/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 03/29/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0123-02386
Permite Description: SFR
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 5/7/24: girder truss missing sufficient support (add 2x's at multiple locations). 8/9/24: seal all penetrations through top plate and vapor barrier, Nail plates required throughout, 18" of copper required before transitioning to pex at water heater, DWV not under test, smoke detector missing outside bedrooms, blocking required at 4-gang box, wire size not per plan throughout, receptacles at bedroom missing at 5' A.F.F, Chimney vent must have a 2" clearance from combustibles, flex must be R-8 if outside of building thermal envelope, kitchen island not installed at time of inspection, STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
| 01/16/2024 | COT - RSPL - Rough Soil | N/A | Partial Pass | under slab ok to backfill |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0123-02386
Permit Description: SFR
Total Completed Inspections - 19
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/29/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 02/29/2024 | COT - RSBU - Preslab | Passed | ||
| 03/01/2024 | COT - RSPL - Sewer | Passed | 3/1/24: sewer connection made to septic ok to backfill. Shading required. | |
| 05/07/2024 | COT - RSBU - Roof Nailing | Passed | ||
| 05/07/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 05/14/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 05/14/2024 | COT - RSEL - Electrical Underground | Passed | 5/14/24: electrical underground at main panel ok to backfill. | |
| 05/14/2024 | BULD - Electrical Clearance | Passed | 5/14/24: TEP ECO CLEARANCE at 3145 W MOCKINGBIRD LN. | |
| 09/17/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 9/17/2024 approved. | |
| 10/02/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 05/22/2025 | COT - FCON - Sprinkler - Final | Passed | ||
| 05/27/2025 | COT - RSPL - Rough Soil | Passed | ||
| 05/27/2025 | COT - RSEL - Outdoor Lighting | Passed | ||
| 05/27/2025 | COT - RSPL - Yard Water Line | Passed | ||
| 06/04/2025 | COT - RSME - Mechanical Final | Passed | Approved. Corrections were made. 6/4/2025 | |
| 06/10/2025 | COT - RSEL - Electrical Final | Passed | Approved. 6/10/2025 | |
| 06/10/2025 | COT - RSPL - Plumbing Final | Passed | Approved. 6/10/2025 | |
| 09/16/2025 | RSBU - Building Final | Passed | ||
| 09/19/2025 | COT - SITE - Zoning Intermediate | Passed | Exterior color scheme meets hillside requirements. Entry is also Zoning Final. Rick Saldate / Nick Ross |