Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 05/27/2025 |
COT - RSME - Mechanical Final |
|
Re-inspection required |
5/27/25: Exterior hose bib must be insulated and wrapped for UV protection, Clean outs must be cut to grade and coated for UV protection, landings required at main entrance and back entry, all plumbing fixture must be installed at time of inspection, water hammer arrestor required at (laundry,refrigerator, dishwasher), vacuum breaker required at hose bibs, outlet kitchen receptacles spacing not code compliance, dishwasher not installed at time of inspection, garbage disposal not installed at time of inspection, vent for vacuum must properly terminate. |
| 06/04/2025 |
COT - RSME - Mechanical Final |
|
Passed |
Approved. Corrections were made. 6/4/2025 |