Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Plumbing Final
Permit Number - TC-RES-0123-02386
Inspection Description - COT - RSPL - Plumbing Final
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/27/2025 | COT - RSPL - Plumbing Final | Re-inspection required | 5/27/25: Exterior hose bib must be insulated and wrapped for UV protection, Clean outs must be cut to grade and coated for UV protection, landings required at main entrance and back entry, all plumbing fixture must be installed at time of inspection, water hammer arrestor required at (laundry,refrigerator, dishwasher), vacuum breaker required at hose bibs, outlet kitchen receptacles spacing not code compliance, dishwasher not installed at time of inspection, garbage disposal not installed at time of inspection, vent for vacuum must properly terminate. | |
| 06/04/2025 | COT - RSPL - Plumbing Final | Re-inspection required | All other items have been completed. Pending two receptacle 2' from sink and dishwasher along with garbage disposal installed. Tighten door hinges in garage to be self closing. Zoning has to be completed prior to final. 6/4/2025 | |
| 06/10/2025 | COT - RSPL - Plumbing Final | Passed | Approved. 6/10/2025 |