| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/06/2026 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 02/12/2026 | APPROVED |
| 01/02/2026 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 01/16/2026 | REQUIRES RESUBMIT |
| 06/02/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 06/02/2026 | APPROVED |
| 02/12/2026 | RESTAMP - RESIDENTIAL v.1 | 02/18/2026 | APPROVED |
Conditions
Permit Number - TC-MDP-1225-00808
Permit Status: Complete
Permit Description: 737-ADU Model Plan (Model Master Plan TC-MDP-1125-00735)
| Date | Description | Comments |
|---|---|---|
| 12/26/2025 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. | |
| 12/26/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 12/26/2025 | Manual J Report | |
| 12/26/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-1225-00808
Permite Description: 737-ADU Model Plan (Model Master Plan TC-MDP-1125-00735)
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 3-10-26: provide a 1 1/2" clearance between DWV & forms, install chairs/blocks throughout pad, footing depth not per plans-a few areas at 21", reinforcement at pad is not per plans-should be #3 rebar @ 24' o.c., add reinforcement, compact pad -noted puddle of water along with water in footing. |
| 03/10/2026 | COT - RSBU - Preslab | N/A | Re-inspection required | 3-10-26: provide a 1 1/2" clearance between DWV & forms, install chairs/blocks throughout pad, footing depth not per plans-a few areas at 21", reinforcement at pad is not per plans-should be #3 rebar @ 24' o.c., add reinforcement, compact pad -noted puddle of water along with water in footing. |
| 03/26/2026 | COT - RSBU - Roof Nailing | N/A | Not Ready | Provide ladder prior to next inspection. 3/26/2026 |
| 03/26/2026 | COT - RSBU - Firewall/Fire Barrier/Firestop | N/A | Partial Pass | Partial pass. 1st fire wall approved. 3/26/2026 |
| 03/26/2026 | COT - RSBU - Interior Shear Bracing | N/A | Partial Pass | Partial pass. 1st fire wall approved. 3/26/2026 |
| 03/26/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Not Ready | Nailing at shear not per schedule throughout. Provide shot pins 6" from edge and 24" o.c. Bottom plate greater than 12" requires two pins. Provide truss calcs prior to next inspection. Interior walls call to be 16" o.c. 24 o.c in field. Stopped inspection. Other items may vary. 3/26/2026 |
| 05/29/2026 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| 05/29/2026 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
| 06/15/2026 | COT - RSPL - Plumbing Final | N/A | Not Ready |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-1225-00808
Permit Description: 737-ADU Model Plan (Model Master Plan TC-MDP-1125-00735)
Total Completed Inspections - 15
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2026 | COT - RSPL - Sewer | Passed | 3” sewer line connected to main sewer line. Ok to cover progress areas. | |
| 03/27/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 04/27/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 05/05/2026 | COT - RSBU - Firewall/Fire Barrier/Firestop | Passed | ||
| 05/05/2026 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 05/05/2026 | COT - RSPL - Yard Water Line | Passed | ||
| 05/11/2026 | BULD - Electrical Clearance | Passed | 05/11/2026 Clearance TEP ECO. |
|
| 05/11/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 05/11/2026 Corrections made to prior inspection. |
|
| 05/29/2026 | COT - RSPL - Rough Soil | Passed | ||
| 06/11/2026 | COT - RSEL - Outdoor Lighting | Passed | ||
| 06/11/2026 | COT - RSME - Mechanical Final | Passed | ||
| 06/11/2026 | ENGR Engineering Final | Passed | Site is complete in accordance with approved plans. | |
| 06/15/2026 | COT - RSEL - Electrical Final | Passed | 06/15/2026 All corrections made to prior inspection. |
|
| 06/15/2026 | RSBU - Building Final | Passed | 06/15/2026 All corrections made to prior inspection. |
|
| 06/16/2026 | COT - RSPL - Plumbing Final | Passed | 06/16/2026 Corrections made to condensate and whips, verified painted exposed plastic. |