Inspection Status: Not Ready

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
03/26/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready Nailing at shear not per schedule throughout. Provide shot pins 6" from edge and 24" o.c. Bottom plate greater than 12" requires two pins. Provide truss calcs prior to next inspection. Interior walls call to be 16" o.c. 24 o.c in field. Stopped inspection. Other items may vary. 3/26/2026
05/11/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 05/11/2026
Corrections made to prior inspection.