Permit: TC-MDP-1025-00695
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
6037 E GABILAN LN
Address NEW:
6037 E GABILAN LN
Apply Date:
10/28/2025
Applicant:
David Alcantar III
Description:
Blackhawk L022 - Etta (Model Master Plan TC-MDP-1025-00677)
Permit Reviews
Permit Number - TC-MDP-1025-00695
Permit Status: Inspections
Permit Description: Blackhawk L022 - Etta (Model Master Plan TC-MDP-1025-00677)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/25/2025 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 11/28/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1025-00695
Permit Status: Inspections
Permit Description: Blackhawk L022 - Etta (Model Master Plan TC-MDP-1025-00677)
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 10/29/2025 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 10/29/2025 | Post-Tension Inspection Report is required. |
| 10/29/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
| 11/25/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 11/25/2025 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-1025-00695
Permit Status: Inspections
Permit Description: Blackhawk L022 - Etta (Model Master Plan TC-MDP-1025-00677)
| Date | Description | Comments |
|---|---|---|
| 10/29/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 10/29/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-1025-00695
Permite Description: Blackhawk L022 - Etta (Model Master Plan TC-MDP-1025-00677)
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2025 | COT - RSEL - Electrical Underground | N/A | Partial Pass | |
| 01/12/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 01/12/2026 Add flat 2x4 on gable end diagonal bracing that exceeds 6’ on northside upstairs, add 6 nails to diagonal bracing on southside gable end, add anchor bolt at marked location and RSP4 on west wall. |
| 03/11/2026 | ENGR Engineering Final | N/A | Not Ready | This permit Is for dwellings, not offices. I recommend you Resubmit TC-COM-1225-02211 call in inspection on that permit. After it is converted back to an SFR, it can be reinspected under the MDP permit. ICC A117.1 requires an Accessible Route. The Landing in front of the Doorway without the step is too steep to comply. The threshold for the doorway of this route should be 1/4”. It can be it to 1/2” if it is beveled. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-1025-00695
Permit Description: Blackhawk L022 - Etta (Model Master Plan TC-MDP-1025-00677)
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2025 | COT - RSPL - Rough Soil | Passed | 12/23/2025 Approved. All fixtures in clean trench with slope holding under test - okay to backfill with shading materials. |
|
| 12/23/2025 | COT - RSPL - Sewer | Passed | 12/23/2025 Approved and holding under to HCS with green tracer - okay to backfill with shading materials. |
|
| 12/23/2025 | COT - RSPL - Yard Water Line | Passed | 12/23/2025 Approved, aquaPEX in trench with blue tracer to meter holding under test - okay to backfill with shading materials. |
|
| 12/29/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 12/29/2025 Approved per site plan. |
|
| 12/29/2025 | COT - RSBU - Preslab | Passed | 12/29/2025 Approved per plan, verified LSTHD8 rebar added and masa clips to rear column. Okay for concrete placement. |
|
| 01/12/2026 | COT - RSBU - Roof Nailing | Passed | 01/12/2026 Approved per plan and truss calcs. |
|
| 01/16/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 01/16/2026 Corrections made to 1/12/26 inspection. |
|
| 01/26/2026 | BULD - Electrical Clearance | Passed | Ready for temp power CLEARANCE ECO | |
| 01/27/2026 | COT - RSPL - Gas Pressure Test | Passed | ||
| 01/27/2026 | RSBU - Building Progress | Passed | ||
| 01/29/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 1/29/26 passed | |
| 02/02/2026 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 03/03/2026 | COT - BULD - SWG Clearance | Passed | 03/03/2026 Approved clearance for SWG. |
|
| 03/11/2026 | COT - RSEL - Outdoor Lighting | Passed | ||
| 03/11/2026 | COT - RSPL - Plumbing Final | Passed | ||
| 03/20/2026 | COT - RSEL - Electrical Final | Passed | 3/20/2026 All corrections are to prior inspection. |
|
| 03/20/2026 | COT - RSME - Mechanical Final | Passed | 3/20/2026 All corrections are to prior inspection. |
|
| 03/20/2026 | RSBU - Building Final | Passed | 3/20/2026 All corrections are to prior inspection. |