Permit: TC-MDP-0626-00414
Permit Details
Status:
In Review
Type:
Model Building Permit
Address:
2421 N COLUMBUS BL UNIT 1
Address NEW:
2421 N COLUMBUS BL UNIT 1
Apply Date:
06/10/2026
Applicant:
Ramon VALDEZ
Description:
Duplex SFR & ADU (Model master plan TC-MDP-1224-01416)
Permit Reviews
Permit Number - TC-MDP-0626-00414
Permit Status: In review
Permit Description: Duplex SFR & ADU (Model master plan TC-MDP-1224-01416)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/23/2026 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 | 08/07/2026 | REQUIRES RESUBMIT |
| 06/26/2026 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 06/26/2026 | REQUIRES RESUBMIT |
| 06/30/2026 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 07/17/2026 | REQUIRES RESUBMIT |
| 08/14/2026 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.4 | N/A | IN REVIEW |
Outstanding Activity Conditions
Permit Number - TC-MDP-0626-00414
Permit Status: In review
Permit Description: Duplex SFR & ADU (Model master plan TC-MDP-1224-01416)
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 06/10/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 06/10/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
| 06/10/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
| 07/15/2026 | An intermediate Elevation Certificate is required PRIOR TO PRE-SLAB INSPECTION. |
| 07/15/2026 | Parcel is located within a regulatory floodplain. Engineering review required prior to issuance, floodplain use permit TE-FPU-0726-00291 must be paid prior to issuance. |
| 07/15/2026 | Submission of the final Elevation Certificate and completion of the Floodplain Use Permit is required PRIOR TO FINALING this permit. |
Conditions
Permit Number - TC-MDP-0626-00414
Permit Status: In review
Permit Description: Duplex SFR & ADU (Model master plan TC-MDP-1224-01416)
| Date | Description | Comments |
|---|---|---|
| 06/30/2026 | Property address on initial submitted plans is already constructed. A sub-records request is needed to correct address to 2421 N Columbus Av, Units 1 & 2. Please contact Pima County Addressing to update address to include unit numbers. Addressing@pima.gov or 520-724-9512 | |
| 08/06/2026 | This project requires a Right-of-Way (ROW) permit issued by Department of Transportation and Mobility (DTM) prior to working in the public Right-of-Way. | |
| 06/10/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |