Permit Number - TC-MDP-0626-00414
Review Name: SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/26/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/26/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-MDP-0626-00414 Location: 2421 N COLUMBUS BL UNITS 1 & 2 Review Date: 8/26/2026 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. Per Right of Way request to revise the existing Development Package (TD-DEV-0924-00270) to maintain safety along Columbus Bl (a Collector in the Major Streets & Routes), Residential Engineering requests the following changes be made to the DP and site plan for this model permit (TC-MDP-0626-00414): - The site plan for the model permit be resubmitted and match the revised DP. - Provide sufficient vehicular maneuverability for both lots (this can be completed by utilizing a recorded cross-access agreement between each parcel: 110075220 & 110075210). This would be needed when utilizing only ONE driveway to access both parcels per ROW comments. Provided recorded sequence on both plans. - Site Engineering recommends the following for exterior access route per Inclusive Home Design: either eliminate it from the West parcel OR create one exterior access route that connects to the East parcel’s exterior access route. This second option would require a recorded pedestrian access agreement and recorded sequence number be provided on both plans. If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 08/26/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-MDP-0626-00414 – Residential Building 2421 N Columbus Bl, Tucson, AZ 85712 Model Building Permit (4th Review) TRANSMITTAL DATE: August 26th, 2026 This site is located in the R-2 zone (UDC 4.7.9). A duplex is a permitted use in this zone with the following use specific standards: 4.9.7.B.6, .8, .9 & .12. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) See comments on access and maneuverability from ROW and Site Engineering. A revision to the approved tentative plat under #TD-DEV-0924-00270 will be required. 2. (Comment) As a revision to the tentative plat is required, please adjust the location of the proposed landscaping from the northwest corner of Lot 1 to the southeast corner of Lot 2. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 08/26/2026 | ROW Engineering Review | REQUIRES RESUBMIT | 1. Columbus is a collector street on the Major Streets and Routes map, onsite maneuverability is required, the designed turnaround area is not sufficient for 3 point turn, use Traffic Engineering turnaround dimensions. Parking should be located outside of vehicular turnaround area if more than one vehicular parking is required. 2. Show proposed Driveway (PAG SD 206), driveway width should not exceed 30’ for shared residential access, 20’ preferred. 3. Show new sidewalk per PAG SD 200, add width 4. Shared access easement required. DTM comment file has been added to attachements |
||
| 08/14/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |