Permit: TC-MDP-0625-00321
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
5740 S NOGALES HY UNIT 5
Address NEW:
5740 S NOGALES HY UNIT 5
Apply Date:
06/06/2025
Applicant:
Jorge Navarro
Description:
Duplex (Model master plan TC-MDP-0724-00807)
Permit Reviews
Permit Number - TC-MDP-0625-00321
Permit Status: Inspections
Permit Description: Duplex (Model master plan TC-MDP-0724-00807)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/05/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 09/19/2025 | REQUIRES RESUBMIT |
| 01/22/2026 | SITE FROM MODEL TEMPLATE INFILL BUILDERS REVISION v.1 | 01/30/2026 | APPROVED |
| 12/04/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 12/12/2025 | APPROVED |
| 12/17/2025 | ADMINISTRATIVE v.1 | 12/17/2025 | REQUIRES RESUBMIT |
| 11/20/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 12/02/2025 | REQUIRES RESUBMIT |
| 12/12/2025 | RESTAMP - RESIDENTIAL v.1 | 12/17/2025 | APPROVED |
| 01/22/2026 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 01/22/2026 | APPROVED |
| 02/18/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/20/2026 | APPROVED |
| 06/09/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 06/24/2025 | REQUIRES RESUBMIT |
| 11/06/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 | 11/06/2025 | APPROVED |
Conditions
Permit Number - TC-MDP-0625-00321
Permit Status: Inspections
Permit Description: Duplex (Model master plan TC-MDP-0724-00807)
| Date | Description | Comments |
|---|---|---|
| 06/09/2025 | The plan submitted shows to be for a duplex BLDG 3 Units 5 & 6. The location 5740 S Nogales Hy does not have BLDG 3 attached to the address and a pre issuance addressing condition has been placed on permit. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify/add the BLDG numbers. An address change request is required to have the bldg number added to this permit. In addition, if the BLDG number ends up different from the ones specified on your site plan and resubmittal may be required as well. | |
| 06/03/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 06/03/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 06/24/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0625-00321
Permite Description: Duplex (Model master plan TC-MDP-0724-00807)
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/24/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Partial Pass | 2-24-26: reinforcement for stem wall at unit's 5 & 6 verified per plans. Okay to grout at 1'. |
| 03/13/2026 | COT - RSBU - Preslab | N/A | Partial Pass | 3-13-26: okay to pour concrete slab on grade @units 5& 6. |
| 05/27/2026 | COT - RSPL - Sewer | N/A | Partial Pass | 5/27/26: Pressure test and piping completed per approved plans. As-built drawings will be required to show the actual location of sewer runs as installed throughout the development. Approved to backfill with the contingency that as-built drawings are submitted prior to final inspection. |
| 05/27/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable | 5-27-26: not applicable |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0625-00321
Permit Description: Duplex (Model master plan TC-MDP-0724-00807)
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2026 | COT - RSPL - Rough Soil | Passed | 03/09/2026 Okay to backfill with shading material. |
|
| 04/15/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 04/15/2026 Approved per plan. Added shot pins on interior sill plates 6" from edges at marked locations. |
|
| 05/04/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 05/04/2026 Approved per plan, added fire foam to top plate penetrations. |
|
| 06/02/2026 | RSBU - Building Progress | Passed |