Permit: TC-MDP-0524-00563
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
6084 E BLACK CAVIAR PL
Address NEW:
6084 E BLACK CAVIAR PL
Apply Date:
05/01/2024
Applicant:
Helen Ormsby
Description:
Blackhawk H30M Model Plan (Model master plan TC-MDP-0823-01436)
Permit Reviews
Permit Number - TC-MDP-0524-00563
Permit Status: Inspections complete
Permit Description: Blackhawk H30M Model Plan (Model master plan TC-MDP-0823-01436)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/02/2024 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 05/13/2024 | APPROVED |
| 10/08/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/09/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0524-00563
Permit Status: Inspections complete
Permit Description: Blackhawk H30M Model Plan (Model master plan TC-MDP-0823-01436)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/01/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0524-00563
Permit Status: Inspections complete
Permit Description: Blackhawk H30M Model Plan (Model master plan TC-MDP-0823-01436)
| Date | Description | Comments |
|---|---|---|
| 05/14/2024 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 05/08/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 05/08/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 05/01/2024 | Post-Tension Inspection Report is required. | |
| 05/01/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 05/08/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 05/08/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0524-00563
Permite Description: Blackhawk H30M Model Plan (Model master plan TC-MDP-0823-01436)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/16/2025 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 9.16.2025 Staples at shear wall throughout needs to be flush - see red markings. HTT4 or 5 not set in place at interior shear walls, add anchor bolts 12" from edge of sole, shear wall at south side requires anchor bolts or masa clips not per schedule, replace section of garage shear wall as marked. Next inspector needs to do full first & second floor walkthrough. STOPPED INSPECTION, MORE ITEMS COULD BE PRESENT. |
| 09/16/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 9.16.2025 Staples at shear wall throughout needs to be flush - see red markings. HTT4 or 5 not set in place at interior shear walls, add anchor bolts 12" from edge of sole throughout, shear wall at south side requires anchor bolts or masa clips not per schedule, replace section of garage shear wall as marked. Next inspector needs to do full first & second floor walkthrough. STOPPED INSPECTION, MORE ITEMS COULD BE PRESENT. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0524-00563
Permit Description: Blackhawk H30M Model Plan (Model master plan TC-MDP-0823-01436)
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/28/2025 | COT - RSPL - Rough Soil | Passed | 8.28.225 All corrections made from prior inspection on 8.26.2025. Okay to backfill with shading. |
|
| 08/28/2025 | COT - RSPL - Sewer | Passed | 8.28.225 All corrections made from prior inspection on 8.26.2025. Okay to backfill with shading. |
|
| 08/28/2025 | COT - RSPL - Yard Water Line | Passed | 8.28.225 All corrections made from prior inspection on 8.26.2025. Okay to backfill with shading. |
|
| 09/04/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 09/04/2025 | COT - RSBU - Preslab | Passed | 9.4.2025 Okay to proceed with concrete placement. |
|
| 09/04/2025 | BULD - Electrical Clearance | Passed | 9.4.2025 Clearance for TEP ECO. |
|
| 09/04/2025 | COT - RSEL - Electrical Underground | Passed | ||
| 09/04/2025 | COT - RSEL - Grounding/Bonding | Passed | ||
| 09/17/2025 | COT - RSBU - Roof Nailing | Passed | ||
| 09/26/2025 | COT - RSPL - Gas Pressure Test | Passed | ||
| 09/30/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 9.30.29 Corrections made |
|
| 09/30/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 10/09/2025 | COT - RSBU - Interior Shear Bracing | Passed | 10.9.25 Approved, proceed |
|
| 11/05/2025 | COT - BULD - SWG Clearance | Passed | 11.05.2025 Clearance for Southwest Gas. |
|
| 11/14/2025 | COT - RSEL - Electrical Final | Passed | ||
| 11/14/2025 | COT - RSEL - Outdoor Lighting | Passed | ||
| 11/14/2025 | COT - RSME - Mechanical Final | Passed | ||
| 11/14/2025 | COT - RSPL - Plumbing Final | Passed | ||
| 11/14/2025 | ENGR Engineering Final | Passed | Site is complete in accordance with approved plans. | |
| 11/14/2025 | RSBU - Building Final | Passed | ||
| 11/14/2025 | RSBU - Building Progress | Passed |