Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0523-01019
Permit Details
Apply Date:
06/09/2023
Applicant:
Daria Hopkins
Description:
SFR MERI156021 T21-M0063
Permit Reviews
Permit Number - TC-MDP-0523-01019
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/15/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/19/2024 | APPROVED |
06/09/2023 | ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 | 06/12/2023 | APPROVED |
Conditions
Permit Number - TC-MDP-0523-01019
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063
Date | Description | Comments |
---|---|---|
06/10/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. | |
06/09/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
06/09/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
08/19/2024 | Post-Tension Inspection Report is required. | |
05/11/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
08/19/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ | |
06/09/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
06/10/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0523-01019
Permite Description: SFR MERI156021 T21-M0063
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/06/2023 | BULD - Electrical Clearance | N/A | Not Ready | 11/6/23: not ready |
11/28/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required (with fee) | Properly install GEC to uffer, seal all penetrations through top plate throughout, wire size in bedrooms (2,3&1) not per plan (12AWG required per plans), secure gas line, shear wall hold down not installed, stopped inspection. Walk house to check for code compliance before calling for inspection. |
03/12/2024 | ENGR Engineering Final | N/A | Not Ready | Grade is a mess between the homes on the left side of the garage. Grade cert. has failed. Please recall when ready |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0523-01019
Permit Description: SFR MERI156021 T21-M0063
Total Completed Inspections - 21