Permit: TC-MDP-0124-00154
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
6034 S JOHN VIC PL
Address NEW:
6034 S JOHN VIC PL
Apply Date:
01/29/2024
Applicant:
David Garcia
Description:
Model1577 New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
Permit Reviews
Permit Number - TC-MDP-0124-00154
Permit Status: Inspections complete
Permit Description: Model1577
New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/31/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 02/16/2024 | REQUIRES RESUBMIT |
| 02/16/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 02/23/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0124-00154
Permit Status: Inspections complete
Permit Description: Model1577
New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 01/30/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 10/19/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0124-00154
Permit Status: Inspections complete
Permit Description: Model1577
New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
| Date | Description | Comments |
|---|---|---|
| 02/23/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 10/12/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0124-00154
Permite Description: Model1577
New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2024 | COT - RSPL - Rough Soil | N/A | Re-inspection required | 4/11/24: No plans on site. No access to site. Please clearly address property. 4/16/24: gray water not per plan, plumbing underground not per plan. |
| 04/24/2024 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 4/24/24: no plans on site. |
| 05/02/2024 | COT - RSBU - Preslab | N/A | Re-inspection required | 4/24/24: no plans on site. 4/26/24: F2 footings missing at garage per plans, M.A.S.A Clips spacing is greater than 32" O.C. 5/2/24: F2 footing missing at toe down at garage missing. |
| 06/14/2024 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 6/11/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). 6/14/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). Revision required for changes in trusses (truss clacs) |
| 02/20/2025 | BULD - Electrical Clearance | N/A | Not Ready | address not found |
| 04/21/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | 4-21-25, not applicable |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0124-00154
Permit Description: Model1577
New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/17/2024 | COT - RSPL - Rough Soil | Passed | 4/11/24: No plans on site. No access to site. Please clearly address property. 4/16/24: gray water not per plan, plumbing underground not per plan. 4/17/24: corrections made ok to backfill. Shading required. Pending sewer connection. |
|
| 05/15/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 4/24/24: no plans on site. 5/15/24: reinforcement per plans ok to proceed. |
|
| 05/15/2024 | COT - RSBU - Preslab | Passed | 4/24/24: no plans on site. 4/26/24: F2 footings missing at garage per plans, M.A.S.A Clips spacing is greater than 32" O.C. 5/2/24: F2 footing missing at toe down at garage missing. 5/15/24: corrections made. Reinforcement per plan ok to proceed. |
|
| 06/24/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 6/11/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). 6/24/24: corrections made ok to proceed |
|
| 06/24/2024 | COT - RSBU - Roof Nailing | Passed | 6/11/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). 6/14/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). Revision required for changes in trusses (truss clacs) 6/24/24: corrections made ok to proceed. |
|
| 07/24/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
| 07/24/2024 | RSBU - Building Progress | Passed | ||
| 07/24/2024 | RSPL - Plumbing Progress | Passed | ||
| 07/24/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 08/21/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 12/30/2024 | COT - RSPL - Yard Water Line | Passed | Per plan, tracer wire present, ok to backfill water line | |
| 01/07/2025 | COT - RSEL - Electrical Underground | Passed | 1-7-25, hcs connection verified with tracer wire. Okay to backfill with shading. | |
| 01/07/2025 | COT - RSPL - Sewer | Passed | 1-7-25, hcs connection verified with tracer wire. Okay to backfill with shading. | |
| 02/20/2025 | BULD - Electrical Clearance | Passed | 2/20/25 approval for TEP ECO | |
| 04/21/2025 | ENGR Engineering Final | Passed | ||
| 05/06/2025 | COT - RSEL - Grounding/Bonding | Passed | 5-6-25, approved. | |
| 05/09/2025 | COT - RSEL - Electrical Final | Passed | 5-9-25, electrical, plumbing, mechanical, and building final approved. Note: there are 2 outstanding conditions. 1) sewer release. 2) truss/joist design. |
|
| 05/09/2025 | COT - RSEL - Outdoor Lighting | Passed | 5-9-25, outdoor lighting approved. | |
| 05/09/2025 | COT - RSME - Mechanical Final | Passed | 5-9-25, electrical, plumbing, mechanical, and building final approved. Note: there are 2 outstanding conditions. 1) sewer release. 2) truss/joist design. |
|
| 05/09/2025 | COT - RSPL - Plumbing Final | Passed | 5-9-25, electrical, plumbing, mechanical, and building final approved. Note: there are 2 outstanding conditions. 1) sewer release. 2) truss/joist design. |
|
| 05/09/2025 | RSBU - Building Final | Passed | 5-9-25, electrical, plumbing, mechanical, and building final approved. Note: there are 2 outstanding conditions. 1) sewer release. 2) truss/joist design. |