Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Address NEW:
6034 S JOHN VIC PL
Apply Date:
01/29/2024
Applicant:
David Garcia
Description:
Model1577 New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson

Permit Reviews

Permit Number - TC-MDP-0124-00154
Permit Status: Inspections complete
Permit Description: Model1577 New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
Start Date Submittal Complete Date Status  
01/31/2024 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 02/16/2024 REQUIRES RESUBMIT Review Details
02/16/2024 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 02/23/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0124-00154
Permit Status: Inspections complete
Permit Description: Model1577 New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
Total Outstanding Activity Conditions - 2
Date Name
01/30/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
10/19/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-MDP-0124-00154
Permit Status: Inspections complete
Permit Description: Model1577 New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
Date Description Comments
02/23/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
10/12/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0124-00154
Permite Description: Model1577 New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
04/16/2024 COT - RSPL - Rough Soil N/A Re-inspection required 4/11/24: No plans on site. No access to site. Please clearly address property.
4/16/24: gray water not per plan, plumbing underground not per plan.
04/24/2024 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required 4/24/24: no plans on site.
05/02/2024 COT - RSBU - Preslab N/A Re-inspection required 4/24/24: no plans on site.
4/26/24: F2 footings missing at garage per plans, M.A.S.A Clips spacing is greater than 32" O.C.
5/2/24: F2 footing missing at toe down at garage missing.
06/14/2024 COT - RSBU - Roof Nailing N/A Re-inspection required 6/11/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02).
6/14/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). Revision required for changes in trusses (truss clacs)
02/20/2025 BULD - Electrical Clearance N/A Not Ready address not found
04/21/2025 COT - BULD - SWG Clearance N/A Not Applicable 4-21-25, not applicable

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0124-00154
Permit Description: Model1577 New Residential Model Plan measuring 1577 SF of Livable space, model to be used at different locations in the city of Tucson
Total Completed Inspections - 21
Date Description Inspector Results Comments
04/17/2024 COT - RSPL - Rough Soil Passed 4/11/24: No plans on site. No access to site. Please clearly address property.
4/16/24: gray water not per plan, plumbing underground not per plan.
4/17/24: corrections made ok to backfill. Shading required. Pending sewer connection.
05/15/2024 COT - RSBU - Excavation/Rebar/Zoning Passed 4/24/24: no plans on site.
5/15/24: reinforcement per plans ok to proceed.
05/15/2024 COT - RSBU - Preslab Passed 4/24/24: no plans on site.
4/26/24: F2 footings missing at garage per plans, M.A.S.A Clips spacing is greater than 32" O.C.
5/2/24: F2 footing missing at toe down at garage missing.
5/15/24: corrections made. Reinforcement per plan ok to proceed.
06/24/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 6/11/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02).

6/24/24: corrections made ok to proceed
06/24/2024 COT - RSBU - Roof Nailing Passed 6/11/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02).
6/14/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). Revision required for changes in trusses (truss clacs)
6/24/24: corrections made ok to proceed.
07/24/2024 COT - RSPL - Gas Pressure Test Passed
07/24/2024 RSBU - Building Progress Passed
07/24/2024 RSPL - Plumbing Progress Passed
07/24/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
08/21/2024 COT - RSBU - Interior Shear Bracing Passed
12/30/2024 COT - RSPL - Yard Water Line Passed Per plan, tracer wire present, ok to backfill water line
01/07/2025 COT - RSEL - Electrical Underground Passed 1-7-25, hcs connection verified with tracer wire. Okay to backfill with shading.
01/07/2025 COT - RSPL - Sewer Passed 1-7-25, hcs connection verified with tracer wire. Okay to backfill with shading.
02/20/2025 BULD - Electrical Clearance Passed 2/20/25 approval for TEP ECO
04/21/2025 ENGR Engineering Final Passed
05/06/2025 COT - RSEL - Grounding/Bonding Passed 5-6-25, approved.
05/09/2025 COT - RSEL - Electrical Final Passed 5-9-25, electrical, plumbing, mechanical, and building final approved.
Note: there are 2 outstanding conditions. 1) sewer release. 2) truss/joist design.
05/09/2025 COT - RSEL - Outdoor Lighting Passed 5-9-25, outdoor lighting approved.
05/09/2025 COT - RSME - Mechanical Final Passed 5-9-25, electrical, plumbing, mechanical, and building final approved.
Note: there are 2 outstanding conditions. 1) sewer release. 2) truss/joist design.
05/09/2025 COT - RSPL - Plumbing Final Passed 5-9-25, electrical, plumbing, mechanical, and building final approved.
Note: there are 2 outstanding conditions. 1) sewer release. 2) truss/joist design.
05/09/2025 RSBU - Building Final Passed 5-9-25, electrical, plumbing, mechanical, and building final approved.
Note: there are 2 outstanding conditions. 1) sewer release. 2) truss/joist design.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
21936_MODEL RESIDENCE 1577_S JOHN VIC PL_COMMENT RESPONSE LETTER_2024-2-9_V1.PDF DOCUMENTS VIEW
A0.1_RESUBMITTAL_V2.PDF DOCUMENTS VIEW
SEWER LOCATION_V1.PDF DOCUMENTS VIEW
21936_MODEL RESIDENCE 1577_S JOHN VIC PL_COMMENT RESPONSE LETTER_2024-2-9_V1.PDF DOCUMENTS VIEW
A0.1_RESUBMITTAL_V2.PDF DOCUMENTS VIEW
SEWER LOCATION_V1.PDF DOCUMENTS VIEW