| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/14/2024 | COT - RSBU - Roof NailingĀ | Re-inspection required | 6/11/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). 6/14/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). Revision required for changes in trusses (truss clacs) |
|
| 06/24/2024 | COT - RSBU - Roof NailingĀ | Passed | 6/11/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). 6/14/24: Anchor bolts required 12" from sill plate edge, anchor bolt spacing not per plan (32" o.c max), simp.ACE4 at headers missing per plan throughout, anchor bolt washer plates must be sized appropriately, 6x6 post at garage missing Simpson DC66, b-2 missing at master bath, roof scuppers missing throughout, beams at back porch not per plan, beam post connection not per plan, anchor bolts missing at sill plate at porch columns,hangers missing at entry porch, beam not per plan at entry porch, clips missing on trusses throughout, truss bracing missing per truss clacs, garage truss not per plan (truss clacs call for B01 and B02). Revision required for changes in trusses (truss clacs) 6/24/24: corrections made ok to proceed. |