Permit: TC-MDP-0124-00154

Parcel: 140252210


Addresses:

6034 S JOHN VIC PL

Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
04/21/2025 RSBU - Building Final  Re-inspection required 4-21-25, fan in not installed in each bathroom, missing smoke detector in bedroom 1, missing plumbing fixture in laundry, install cooktop and dishwasher, insulate hose bib located on north side, lower thermostat to 48" o.c., vacuum breaker required on south hose bib, cut cleanouts to grade, landscape in its current state is not per code-remove any excess concrete near foundation/footing and provide ladder for roof access. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED.
05/06/2025 RSBU - Building Final  Re-inspection required 5-6-25, missing hammer arrestor on dishwasher, bury grounding rods, arch-fault breakers are required for kitchens, bedrooms dining rooms, laundry rooms, living/family rooms. Cleanout near back wall is not to grade, paint all exterior plastics, and provide lockout at the main panel for each water heater breaker
05/09/2025 RSBU - Building Final  Passed 5-9-25, electrical, plumbing, mechanical, and building final approved.
Note: there are 2 outstanding conditions. 1) sewer release. 2) truss/joist design.