Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Needs Resubmittal
Type:
Commercial Building
Address NEW:
330 N COMMERCE PARK LP
Apply Date:
11/05/2025
Applicant:
Cary Broschat
Description:
Installation of PV Solar shade canopies in parking lot of United Way 210.68 KW dc/ 161 KW ac associated DP- TD-DEV-0625-00167

Permit Reviews

Permit Number - TC-COM-1125-02029
Permit Status: Needs resubmittal
Permit Description: Installation of PV Solar shade canopies in parking lot of United Way 210.68 KW dc/ 161 KW ac associated DP- TD-DEV-0625-00167
Start Date Submittal Complete Date Status  
04/27/2026 SPECIAL INSPECTION REVIEW v.1 04/28/2026 REQUIRES RESUBMIT Review Details
11/06/2025 COMMERCIAL REVIEW - FULL v.1 12/03/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-1125-02029
Permit Status: Needs resubmittal
Permit Description: Installation of PV Solar shade canopies in parking lot of United Way 210.68 KW dc/ 161 KW ac associated DP- TD-DEV-0625-00167
Total Outstanding Activity Conditions - 2
Date Name
11/28/2025 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
11/28/2025 SPECIAL INSPECTION FOR SPECIAL MOMENT RESISTING STEEL FRAMES IS REQUIRED.

Conditions

Permit Number - TC-COM-1125-02029
Permit Status: Needs resubmittal
Permit Description: Installation of PV Solar shade canopies in parking lot of United Way 210.68 KW dc/ 161 KW ac associated DP- TD-DEV-0625-00167
Date Description Comments
11/28/2025 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
12/01/2025 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
11/28/2025 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.
11/28/2025 SPECIAL INSPECTION FOR WELDING IS REQUIRED.

Outstanding Inspections

Permit Status: Needs Resubmittal
Permit Number: TC-COM-1125-02029
Permite Description: Installation of PV Solar shade canopies in parking lot of United Way 210.68 KW dc/ 161 KW ac associated DP- TD-DEV-0625-00167
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
02/09/2026 COT - LCBU - Excavation/Rebar/Zoning N/A Partial Pass
02/09/2026 COT - CSOL - Electrical Underground Solar Project N/A Partial Pass

Completed Inspections

Permit Status: Needs Resubmittal
Permit Number: TC-COM-1125-02029
Permit Description: Installation of PV Solar shade canopies in parking lot of United Way 210.68 KW dc/ 161 KW ac associated DP- TD-DEV-0625-00167
Total Completed Inspections - 12
Date Description Inspector Results Comments
03/09/2026 COT - LCBU - Excavation/Rebar/Zoning Passed Passed for final canopy 3/9/26
03/09/2026 COT - CSOL - Electrical Underground Solar Project Passed Passed for final canopy 3/9/26
03/28/2026 Building Inspection - Outside Normal Hours Building Inspection Passed 03/28/2026
Approved per plan. Verified 300A backfeed breaker at switchgear box point of interconnection. Verified ACDS-01 disconnect switch and fuses. Okay to proceed in progress areas.
04/15/2026 BULD - Electrical Clearance Passed Clearance to TEP DGC. 4/15/2026
04/15/2026 COT - CSOL - Electrical Final Solar Project Passed
04/15/2026 COT - CSOL - Electrical Intermediate Solar Project Passed
04/15/2026 COT - CSOL - Outdoor Lighting Solar Project Passed
04/15/2026 COT - FCON - Fire - Final Passed
04/15/2026 COT - LCBU - Building Final Passed
04/15/2026 TRSP - ROW - Final/Close-Out Passed
04/15/2026 PDSD Building Division Pre-Construction Meeting Passed
04/17/2026 ENGR Engineering Final Passed There is equipment, connex box, dumpster etc that will be used for other permits. This is all secured by fencing without blocking access.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-UNITED WAY - METER 1_IFP SET_251105_V1.PDF DOCUMENTS VIEW
COT - UNITED WAY METER 1 - SI FORM_SIGNED-2025-11-05_V1.PDF DOCUMENTS VIEW
UNITED WAY - METER 1_GEOTECH_V1.PDF DOCUMENTS VIEW
UNITED WAY - METER 1_STRUCTURAL CALCULATIONS_V1.PDF DOCUMENTS VIEW