Permit: TC-COM-1023-02382
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
3820 E FORT LOWELL RD
Address NEW:
3820 E FORT LOWELL RD
Apply Date:
10/10/2023
Applicant:
burak bekat
Description:
REV1: Revised unit addresses New 2 story multifamily building with 8 units
Permit Reviews
Permit Number - TC-COM-1023-02382
Permit Status: Inspections
Permit Description: REV1: Revised unit addresses
New 2 story multifamily building with 8 units
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/11/2023 | COMMERCIAL REVIEW - FULL v.1 | 11/02/2023 | REQUIRES RESUBMIT |
| 08/27/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/28/2025 | APPROVED |
| 01/04/2024 | RESTAMP - COMMERCIAL v.1 | 01/09/2024 | APPROVED |
| 11/30/2023 | COMMERCIAL REVIEW - FULL v.2 | 12/06/2023 | REQUIRES RESUBMIT |
| 12/03/2025 | COMMERCIAL REVIEW - FULL v.1 | 12/30/2025 | APPROVED |
| 12/19/2023 | COMMERCIAL REVIEW - FULL v.3 | 01/04/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-1023-02382
Permit Status: Inspections
Permit Description: REV1: Revised unit addresses
New 2 story multifamily building with 8 units
Total Outstanding Activity Conditions - 7
| Date | Name |
|---|---|
| 01/04/2024 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
| 01/04/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 01/04/2024 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
| 01/04/2024 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
| 01/04/2024 | SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED. |
| 06/24/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
| 12/18/2025 | SPECIAL INSPECTION FOR SPECIAL MOMENT RESISTING STEEL FRAMES IS REQUIRED. |
Conditions
Permit Number - TC-COM-1023-02382
Permit Status: Inspections
Permit Description: REV1: Revised unit addresses
New 2 story multifamily building with 8 units
| Date | Description | Comments |
|---|---|---|
| 10/11/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 10/11/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 12/18/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. | |
| 01/04/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-1023-02382
Permite Description: REV1: Revised unit addresses
New 2 story multifamily building with 8 units
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2025 | COT - HCPL - Plumbing Roof Drains | N/A | Not Ready | |
| 10/31/2025 | COT - HCPL - Plumbing Intermediate | N/A | Partial Pass | |
| 10/29/2025 | COT - HCME - Mechanical Intermediate | N/A | Partial Pass | |
| 12/23/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 11/10/2025 | COT - HCBU - Stem Wall/Retaining Wall | N/A | Partial Pass | Wall on North side, reinforcement and height are good, okay to grout final lift. |
| 12/30/2025 | COT - HCBU - Building Final | N/A | Partial Pass | Partial pass. Okay for level 4 TCO. 12/30/2025 |
| 12/30/2025 | COT - FCON - Alarm - Final | N/A | Not Ready | |
| COT - FCON - Fire - Final | N/A | Not Ready | Called in wrong inspection. | |
| 12/30/2025 | TRSP - ROW - Final/Close-Out | N/A | Re-inspection required |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-1023-02382
Permit Description: REV1: Revised unit addresses
New 2 story multifamily building with 8 units
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2025 | COT - HCPL - Rough Soil | Passed | ||
| 07/15/2025 | COT - HCPL - Yard Water Line | Passed | ||
| 08/28/2025 | COT - HCBU - Roof Nailing | Passed | ||
| 09/18/2025 | COT - HCBU - Preslab | Passed | ||
| 10/01/2025 | COT - HCPL - Plumbing Roof Drains | Passed | ||
| 10/14/2025 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. House panel, 201,202,203,204,101,102,103,&104. 10/14/2025 | |
| 10/24/2025 | COT - HCBU - Framing | Passed | ||
| 11/13/2025 | COT - HCPL - Plumbing Intermediate | Passed | ||
| 11/13/2025 | COT - HCEL - Electrical Intermediate | Passed | ||
| 11/13/2025 | COT - HCME - Mechanical Intermediate | Passed | ||
| 12/12/2025 | COT - HCEL - Electrical Underground | Passed | ||
| 12/19/2025 | COT - HCPL - Plumbing Final | Passed | ||
| 12/23/2025 | COT - HCBU - Stem Wall/Retaining Wall | Passed | ||
| 12/23/2025 | COT - HCME - Mechanical Final | Passed | ||
| 12/23/2025 | COT - HCEL - Electrical Final | Passed | ||
| 12/30/2025 | COT - FCON - Sprinkler - Final | Passed | ||
| 12/30/2025 | ENGR Engineering Final | Passed | Site is safe and accessible, complete in accordance with approved plans. | |
| 01/06/2026 | TRSP - ROW - Final/Close-Out | Passed |