Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Not Ready

Inspection History: COT - HCPL - Plumbing Roof Drains

Permit Number - TC-COM-1023-02382

Inspection Description - COT - HCPL - Plumbing Roof Drains

Inspection Status - Not Ready

Date Description Inspector Results Comments
09/19/2025 COT - HCPL - Plumbing Roof Drains Not Ready
09/25/2025 COT - HCPL - Plumbing Roof Drains Partial Pass Partial pass. Roof drains on test approved. Pending bracing at every 4' horizontally. Provide bracing vertically along with Boca plates at both top and bottom plates. 9/25/2025
09/29/2025 COT - HCPL - Plumbing Roof Drains Not Ready
10/01/2025 COT - HCPL - Plumbing Roof Drains Passed