Permit: TC-COM-0925-01611
Permit Details
Status:
Issued
Type:
Commercial Building
Address:
8650 S ALVERNON WY
Address NEW:
8650 S ALVERNON WY
Apply Date:
09/02/2025
Applicant:
Ian Regan
Description:
Construction of Outdoor Concrete Equipment Test Pad - Ref.: TD-DEV-0325-00075 3500000.00
Permit Reviews
Permit Number - TC-COM-0925-01611
Permit Status: Issued
Permit Description: Construction of Outdoor Concrete Equipment Test Pad -
Ref.: TD-DEV-0325-00075 3500000.00
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/27/2026 | SPECIAL INSPECTION REVIEW v.1 | 04/29/2026 | APPROVED |
| 01/23/2026 | COMMERCIAL REVIEW - LIMITED v.3 | 02/09/2026 | REQUIRES RESUBMIT |
| 09/30/2025 | COMMERCIAL REVIEW - LIMITED v.2 | 10/21/2025 | REQUIRES RESUBMIT |
| 09/04/2025 | COMMERCIAL REVIEW - LIMITED v.1 | 09/22/2025 | REQUIRES RESUBMIT |
| 04/06/2026 | ADMINISTRATIVE v.1 | 04/06/2026 | REQUIRES RESUBMIT |
| 03/05/2026 | COMMERCIAL REVIEW - LIMITED v.4 | 03/25/2026 | APPROVED |
| 04/27/2026 | ADMINISTRATIVE v.2 | N/A | IN REVIEW |
| 06/26/2026 | SPECIAL INSPECTION REVIEW v.1 | 06/29/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0925-01611
Permit Status: Issued
Permit Description: Construction of Outdoor Concrete Equipment Test Pad -
Ref.: TD-DEV-0325-00075 3500000.00
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 04/28/2026 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
| 04/28/2026 | Post-Installed Anchor Inspection Report is required. |
| 04/28/2026 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
| 06/29/2026 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. |
Conditions
Permit Number - TC-COM-0925-01611
Permit Status: Issued
Permit Description: Construction of Outdoor Concrete Equipment Test Pad -
Ref.: TD-DEV-0325-00075 3500000.00
| Date | Description | Comments |
|---|---|---|
| 09/19/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 09/04/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 09/04/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 09/19/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-0925-01611
Permite Description: Construction of Outdoor Concrete Equipment Test Pad -
Ref.: TD-DEV-0325-00075 3500000.00
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/03/2026 | COT - LCEL - Grounding/Bonding | N/A | Partial Pass | 6/3/26: #3/0 ground from electrical system grd bus to test stand pad#1 per approved plans, #3/0 ground from SWGR to test stand pad #2 per approved plans ok to proceed with backfill. |
| 06/26/2026 | COT - LCEL - Electrical Underground | N/A | Partial Pass | 6-26-26: verified 4 electrical schedule 40 conduit stub-ups to pull boxes and a total of 4 Caldwell grounds (3/0 ) to reinforcement on future slab on grade. 2 grounds at reinforcement located at the northeast section and the other set located near the center of slab. Okay to backfill progress areas using shading materials. |
| 07/01/2026 | COT - LCBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 7-1-26: called POC at 723am and left message advising that I would be on site in the next 5 minutes. Arrived on site at 727am and waited for an escort at Gate 81A. I waited until 737am and left. Reschedule inspection when ready. Note: another failed inspection will result with a re-inspection fee. |
| 06/08/2026 | COT - LCBU - Preslab | N/A | Partial Pass | 6/8/26: GL 1 and 3 ready for concrete placement ( submit revised set of plans on DP to accurately reflect 5" Concrete over 4" ABC) |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-0925-01611
Permit Description: Construction of Outdoor Concrete Equipment Test Pad -
Ref.: TD-DEV-0325-00075 3500000.00
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/14/2026 | PDSD Building Division Pre-Construction Meeting | Passed |
Scheduled Inspections
Scheduled Inspections - TC-COM-0925-01611
Status: Issued
Description: Construction of Outdoor Concrete Equipment Test Pad -
Ref.: TD-DEV-0325-00075 3500000.00
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 07/02/2026 | COT - LCBU - Preslab | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.