Description:
Addition of two exterior exiting stairways to existing sleeping area. One on the east side and one on the west side
Permit Reviews
Permit Number - TC-COM-0625-01147
Permit Status: Complete
Permit Description: Addition of two exterior exiting stairways to existing sleeping area. One on the east side and one on the west side
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/06/2025 | COMMERCIAL REVIEW - FULL v.3 | 08/12/2025 | REQUIRES RESUBMIT |
| 08/22/2025 | COMMERCIAL REVIEW - FULL v.4 | 08/26/2025 | APPROVED |
| 10/14/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/15/2025 | APPROVED |
| 07/16/2025 | COMMERCIAL REVIEW - FULL v.2 | 08/05/2025 | REQUIRES RESUBMIT |
| 06/12/2025 | COMMERCIAL REVIEW - FULL v.1 | 07/07/2025 | REQUIRES RESUBMIT |
| 08/26/2025 | RESTAMP - COMMERCIAL v.1 | 09/09/2025 | APPROVED |
| 10/20/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/20/2025 | APPROVED |
Conditions
Permit Number - TC-COM-0625-01147
Permit Status: Complete
Permit Description: Addition of two exterior exiting stairways to existing sleeping area. One on the east side and one on the west side
| Date | Description | Comments |
|---|---|---|
| 08/11/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 10/09/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 08/11/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 08/11/2025 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. | |
| 08/11/2025 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. | |
| 06/30/2025 | IBC 1004.5.1 allows the increased occupant load of the Sleeping Room. The occupant load of the Sleeping Room stating "Not to exceed 40 Occupants", along with a specific egress path diagram signage in the Sleeping Room to align with the specific egress path on the floor plan. | |
| 08/11/2025 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. | |
| 08/11/2025 | Masonry Inspection Report submittal review is required. | |
| 08/11/2025 | Post-Installed Anchor Inspection Report is required. | |
| 06/12/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 08/11/2025 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 08/11/2025 | SPECIAL INSPECTION FOR COLD-FORMED STEEL DECK IS REQUIRED | |
| 08/11/2025 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-0625-01147
Permit Description: Addition of two exterior exiting stairways to existing sleeping area. One on the east side and one on the west side
Total Completed Inspections - 22