Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
In Revision
Type:
Commercial Building
Address NEW:
5651 S HOUGHTON RD
Apply Date:
05/15/2025
Applicant:
Dave Damitio
Description:
New McDonald's building

Permit Reviews

Permit Number - TC-COM-0525-01005
Permit Status: In revision
Permit Description: New McDonald's building
Start Date Submittal Complete Date Status  
09/09/2025 COMMERCIAL REVIEW - FULL v.3 09/18/2025 APPROVED Review Details
02/03/2026 COMMERCIAL REVIEW - FULL REVISION v.1 N/A IN REVIEW Review Details
09/22/2025 ADMINISTRATIVE v.1 09/22/2025 REQUIRES RESUBMIT Review Details
09/18/2025 RESTAMP - COMMERCIAL v.1 09/22/2025 APPROVED Review Details
05/16/2025 COMMERCIAL REVIEW - FULL v.1 06/20/2025 REQUIRES RESUBMIT Review Details
07/24/2025 COMMERCIAL REVIEW - FULL v.2 08/15/2025 REQUIRES RESUBMIT Review Details
12/18/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 12/26/2025 APPROVED Review Details
10/24/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 10/27/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0525-01005
Permit Status: In revision
Permit Description: New McDonald's building
Total Outstanding Activity Conditions - 5
Date Name
07/31/2025 Prior to project being finalized applicant must provide recorded documents for the water and electrical easements shown to be recorded under separate instruments on sheet SP1 of TD-DEV-0525-00132
08/07/2025 SPECIAL INSPECTION FOR OUTDOOR LIGHTING IS REQUIRED.
09/10/2025 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
09/10/2025 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
09/10/2025 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.

Conditions

Permit Number - TC-COM-0525-01005
Permit Status: In revision
Permit Description: New McDonald's building
Date Description Comments
05/16/2025 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
05/16/2025 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
08/07/2025 An Outdoor Lighting Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf
09/10/2025 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: In Revision
Permit Number: TC-COM-0525-01005
Permite Description: New McDonald's building
Total Outstanding Inspections - 11
Last Inspection Date Description Inspector Results Comments
12/12/2025 COT - HCEL - Grounding/Bonding N/A Partial Pass 12.12.25
Partial for ufer only
12/15/2025 zzzPDSD Building Division - Site Excavation/Layout/Rebar N/A Not Ready
12/18/2025 COT - HCBU - Building Progress N/A Partial Pass
01/06/2026 COT - HCPL - Rough Soil N/A Partial Pass underslab
01/09/2026 COT - HCEL - Electrical Intermediate N/A Partial Pass Electrical underground inspection. All branch circuits in kitchen areas ran to the main distributing panel and other miscellaneous equipment. Okay to backfill progress areas in pad. 1/9/2026
01/17/2026 COT - HCPL - Sewer N/A Re-inspection required 1/16/26: Missing Clean out per C500 detail 2, two-way clean out not per plans at 2" connection to building per detail 6, 2" vent for grease trap must have tracer wire attached to plumbing underground. Corrections must be made prior to backfill.
COT - LCPL - Yard Water Line N/A Requested
COT - HCBU - Exterior Clips/Sheathing N/A Scheduled
02/04/2026 COT - HCBU - Roof Nailing N/A Canceled Pre-slab has not passed.
01/17/2026 COT - HCBU - Preslab N/A Re-inspection required 1/16/26: continuous #5 rebar missing at slab per detail S2.3 with additional #4x32" long dowels at 16" o.c at doors, all columns base must be coated with asphaltic paint below grade, holdowns missing at all shear-walls per approved plans, reinforcement not in place around freezer pad per detail S2.7 (missing 2#6 continuous around pad), will need to verify (3) 2x10 redwood sleepers at freezer pad, Recessed slab for mop sinks missing per approved plans at two locations, vapor barrier was never inspected.
COT - HCBU - Framing N/A Scheduled

Completed Inspections

Permit Status: In Revision
Permit Number: TC-COM-0525-01005
Permit Description: New McDonald's building
Total Completed Inspections - 5
Date Description Inspector Results Comments
12/04/2025 BULD - Electrical Clearance Passed 12.4.25
Approved for temp power
12/04/2025 COT - HCEL - Electrical Underground Passed 12.4.25
Conduit type and depth from panel to transformer verified and approved
12/11/2025 COT - HCEL - Electrical Progress Passed 12.4.25
Proceed
Ok to backfill progress areas
12/12/2025 COT - HCBU - Excavation/Rebar/Zoning Passed Approved to pour
02/05/2026 COT - HCPL - Yard Water Line Passed

Scheduled Inspections

Scheduled Inspections - TC-COM-0525-01005
Status: In Revision
Description: New McDonald's building
Scheduled Date Description Entered By Entered Date
02/06/2026 COT - HCBU - Roof Nailing Scheduled
02/06/2026 COT - HCBU - Preslab Scheduled
02/06/2026 COT - HCBU - Exterior Clips/Sheathing Scheduled
02/06/2026 COT - HCBU - Framing Scheduled
For information about today’s scheduled inspections please refer to the PDSD Daily Inspections Dashboards (Desktop) PDSD Daily Inspections Dashboards (Mobile) .

Documents

File Name Document Type  
DEFERRED SUBMITTAL_TRUSS_V1.PDF DOCUMENTS VIEW
TC-COM-0525-01005 STEM WALL FOOTING 1_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-3_TC-COM-0525-01005_BUILDING PLANS_V3.PDF DOCUMENTS VIEW