Permit Details

Status:
Revoked
Type:
SINGLE FAMILY NEW
Address NEW:
441 W DAKOTA ST #01
Apply Date:
05/13/1998
Applicant:
KONARSKI FRANK J & GABRIELA JT/R
Description:
FOURPLEX
Architects:
  • KELLEY, ANDREW SCOTT
Contractors:
  • F G P J DEVELOPMENT ,

Permit Reviews

Permit Number - T98CM02096
Permit Status: Revoked
Permit Description: FOURPLEX
Start Date Submittal Complete Date Status  
03/10/2008 COMMERCIAL-BLDG/FIRE/ZONING/ENG 03/28/2008 COMPLETED Review Details
03/28/2008 3RD PARTY REVIEW-COMMERCIAL 04/03/2008 COMPLETED Review Details
04/03/2008 REVISION - - 1ST 05/27/2008 COMPLETED Review Details
05/27/2008 REVISION - - 1ST 09/16/2008 COMPLETED Review Details
09/16/2008 REVISION - SITE 09/18/2008 COMPLETED Review Details
10/24/2000 REVISION 02/14/2001 COMPLETED Review Details

Outstanding Inspections

Permit Status: Revoked
Permit Number: T98CM02096
Permite Description: FOURPLEX
Total Outstanding Inspections - 25
Last Inspection Date Description Inspector Results Comments
STEM WALL/RETAINING WALL N/A Not Inspected
BUILDING PRE-SLAB N/A Not Inspected
REINFORCED MASONRY PRE-GROUT N/A Not Inspected
U VALUE FOR WINDOW N/A Not Inspected
SHEET ROCK NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
ELECTRIC - UFER N/A Not Inspected
PLUMBING - GAS PRESSURE TEST N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
MECHANICAL - INTERMEDIATE N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
FIRE - FINAL N/A Not Inspected
LANDSCAPE - FINAL N/A Not Inspected
PERMIT FINALED N/A Not Inspected
01/24/2008 ROOF NAILING N/A Partial Approval IVRS - Inspection :*
1. PLANS MUST BE REVISED FOR C.O.T APPROVAL TO MATCH AS BUILT
2. TRUSS DRAWINGS MUST BE APPROVED
3. OK TO DRY IN ROOF AT YOUR OWN RISK - SHEATHING IS OK REVISED PLANS REQUIRED
01/24/2008 ELECTRIC - INTERMEDIATE N/A Not ready for Inspection IVRS - Inspection :*
INSTALL BONDING RING ON RISER
03/10/2005 ENGINEERING - FINAL N/A Denied SITE NOT READY AT THIS TIME. COMPLETE ALL WORK FOR THE STRUCTURE PRIOR TO CALLING FOR A RE-INSPECTION FOR THIS SITE.
03/10/2008 ELECTRIC - FINAL N/A Not ready for Inspection
03/10/2008 PLUMBING - INTERMEDIATE N/A Partial Approval UNDERGROUND FOR REVISION 1 PLUMBING OK TO COVER (BATHROOMS)
03/20/2008 STUCCO MESH N/A Partial Approval IVRS - Inspection :*
05/10/2000 EXCAVATION/LAYOUT REBAR & ZON N/A Correction Required ADDTL COMMS - 1. PROVIDE MIN 3 1/2 CONCRET ON TO 4 SLAB
09/17/2004 ELECTRIC - UNDERGROUND N/A Partial Approval IVRS - Inspection :* OK ?, CABLE, POWER TO BEYOND SIDE WALK SOUTH END OF BLD
11/28/2001 BUILDING - PROGRESS N/A Denied PROVIDE APPROVED PLANS FROM CITY OF TUCSON FOR PERIMETER WALL. YOU NEED A PERMIT FOR 6' WALL. CALLED FOR PROGRESS INSPECTION ON 4-PLEX HAD FOOTING FOR WALL READY, BUT WALL IS NOT PART OF THIS PERMIT. ADDITIONAL PERMIT REQUIRED FOR WALL.PERMIT SHOULDNT HAVE EXPIRED.THERE HAVE BEEN NO INSPECTION ON THIS PERMIT SINCE MAY OF 2000 THERE HAS BEEN NO PROGRESS HAS BEEN MADE ON4-PLEX FOR OVER 1 YEAR! EXPIRED PERMIT PER STEVE LONG.
12/14/2007 ELECTRIC - TEMP POWER FOR TEST N/A Not ready for Inspection 1) YOU NEED #4 GROUNDING ELECTRODE CONDUCTOR CONNECTED TO 2 EACH GROUND RODS.

2) GROUNDING RODS NEED TO BE 6' APART.

3) YOU NEED TO HAVE YOUR TEMP MOUNTING PANEL SECURE. IT MAY NOT ROCK, TWIST, ETC.

4) YOU NEED TO CONNECT YOU METER SOCKET TO THE DISCONNECT PANEL. TEP DOES NOT SUPPLY THE METER SOCKET...ONLY THE WIRE FROM THE METER TO THE POLE.
12/21/2007 FRAMING N/A Not ready for Inspection IVRS - Inspection :*
1) RECALL WHEN PLUMBING AND ELECTRIC IN

Completed Inspections

Permit Status: Revoked
Permit Number: T98CM02096
Permit Description: FOURPLEX
Total Completed Inspections - 7
Date Description Inspector Results Comments
05/12/2000 PLUMBING - ROUGH, SOIL TRINIVJR Approved ADDTL COMMS - 1. SOIL WATER TEST OK
05/17/2000 PLUMBING - SEWER HCS CONNECT JSTANLEY Approved ADDTL COMMS - TEST ON SITE SEWER FROM EXISTING HCS TO BLDG TEST OK. OK TO BACKFILL
05/22/2000 PLUMBING - YARD WTR LINE/TEST JSTANLEY Approved ADDTL COMMS - TEST ON SITE WATER OK REVISED PLAN ON FILE OK TO BACKFILL
12/21/2007 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection :*
1) INSTALL LT ANCHORS AT 8 LOCATIONS (6 BACK AND 2 FRONT) TO CORRECT SHEAR PANELS
2) YOU CAN USE LTT131 ? LTT 19 WITH 3/4" EPOXIED ANCHOR BOLT OR AN HTT
3) OK TO LATH
03/10/2008 ELECTRIC - TEMPORARY SERVICE LHANLY Approved
03/10/2008 ELECTRIC - CABLE DROP LHANLY Approved
03/11/2008 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR "4-PLEX" PER L. HANLY