Permit: T22CM07465
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
109 W CALLE MARGARITA
Address NEW:
109 W CALLE MARGARITA
Apply Date:
09/28/2022
Applicant:
Martin Mendoza
Description:
R-ENCLOSED PORCH FOR MASTER BEDROOM W/BATH CLOSET AND EXTEND DINNING ROOM
Permit Reviews
Permit Number - T22CM07465
Permit Status: Issued
Permit Description: R-ENCLOSED PORCH FOR MASTER BEDROOM W/BATH CLOSET AND EXTEND DINNING ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/28/2022 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 10/17/2022 | COMPLETED |
| 05/18/2023 | RESIDENTIAL NEW DWELLING v.1 | 06/16/2023 | APPROVED |
| 01/23/2023 | RESIDENTIAL NEW DWELLING v.1 | 02/07/2023 | APPROVED |
Conditions
Permit Number - T22CM07465
Permit Status: Issued
Permit Description: R-ENCLOSED PORCH FOR MASTER BEDROOM W/BATH CLOSET AND EXTEND DINNING ROOM
| Date | Description | Comments |
|---|---|---|
| 03/17/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM07465
Permite Description: R-ENCLOSED PORCH FOR MASTER BEDROOM W/BATH CLOSET AND EXTEND DINNING ROOM
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/28/2023 | COT - RSBU - Masonry Pregrout | N/A | Partial Pass | 6-28-23: First lift. Note: Existing bedroom window compliant with emergency escape and rescue requirements of the IRC has been closed up per plan; side window will now need to be modified to comply with emergency escape and rescue opening requirements of IRC. Homeowner notified today. Front attached porch has combustible construction within 3 feet of property line, not shown on plans; will need to be mitigated prior to Final Inspection. |
| 11/03/2023 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
| 11/03/2023 | COT - BULD - SWG Clearance | N/A | Not Applicable |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM07465
Permit Description: R-ENCLOSED PORCH FOR MASTER BEDROOM W/BATH CLOSET AND EXTEND DINNING ROOM
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/22/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Footing are dug per plans. Okay to pour concrete footing. | |
| 06/12/2023 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading required. 6/12/2023 | |
| 07/26/2023 | BULD - Electrical Clearance | Passed | Electrical panel is installed on exterior wall with 2 ground rods 6' apart. Okay to energize system. INCR Clearance issued. | |
| 07/26/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | H2.5 clips are installed properly. Okay to install roofing once electrical is moved to exterior wall. | |
| 08/28/2023 | COT - RSBU - Masonry Pregrout | Passed | 8/28/23 okay to grout final lift for carport wall extension | |
| 09/01/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 6-28-23: First lift. Note: Existing bedroom window compliant with emergency escape and rescue requirements of the IRC has been closed up per plan; side window will now need to be modified to comply with emergency escape and rescue opening requirements of IRC. Homeowner notified today. Front attached porch has combustible construction within 3 feet of property line, not shown on plans; will need to be mitigated prior to Final Inspection. Not ready. Pending intermediate inspections corrected. Missing smoke detectors in bedroom and outside of bedroom. Add nail plates to plumbing lines that are less than an 1" 1/4. Fire foam all top penetrations. Add ground screws to fan boxes. Laundry line has created an S trap. Need minimum 4". Secure pex line above ceiling in bathroom. 8/28/2023 9/1/23: all corrections made |
|
| 11/03/2023 | COT - RSBU - Preslab | Passed | ||
| 11/03/2023 | RSBU - Building Final | Passed |