Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T22CM07465

Parcel: 138142060

Inspection Status: Not Ready

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
06/28/2023 RSBU - Building Final  Not Ready 6-28-23: First lift.
Note: Existing bedroom window compliant with emergency escape and rescue requirements of the IRC has been closed up per plan; side window will now need to be modified to comply with emergency escape and rescue opening requirements of IRC. Homeowner notified today.
Front attached porch has combustible construction within 3 feet of property line, not shown on plans; will need to be mitigated prior to Final Inspection.
08/28/2023 RSBU - Building Final  Re-inspection required Not ready. Pending intermediate inspections corrected. Missing smoke detectors in bedroom and outside of bedroom. Add nail plates to plumbing lines that are less than an 1" 1/4. Fire foam all top penetrations. Add ground screws to fan boxes. Laundry line has created an S trap. Need minimum 4". Secure pex line above ceiling in bathroom. 8/28/2023
09/01/2023 RSBU - Building Final  Partial Pass 6-28-23: First lift.
Note: Existing bedroom window compliant with emergency escape and rescue requirements of the IRC has been closed up per plan; side window will now need to be modified to comply with emergency escape and rescue opening requirements of IRC. Homeowner notified today.
Front attached porch has combustible construction within 3 feet of property line, not shown on plans; will need to be mitigated prior to Final Inspection.


Not ready. Pending intermediate inspections corrected. Missing smoke detectors in bedroom and outside of bedroom. Add nail plates to plumbing lines that are less than an 1" 1/4. Fire foam all top penetrations. Add ground screws to fan boxes. Laundry line has created an S trap. Need minimum 4". Secure pex line above ceiling in bathroom. 8/28/2023

9/1/23: all corrections made
11/03/2023 RSBU - Building Final  Passed