Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T22CM07465

Parcel: 138142060

Inspection Status: Partial Pass

Inspection History: COT - RSBU - Masonry Pregrout 

Date Description Inspector Results Comments
06/28/2023 COT - RSBU - Masonry Pregrout  Partial Pass 6-28-23: First lift.
Note: Existing bedroom window compliant with emergency escape and rescue requirements of the IRC has been closed up per plan; side window will now need to be modified to comply with emergency escape and rescue opening requirements of IRC. Homeowner notified today.
Front attached porch has combustible construction within 3 feet of property line, not shown on plans; will need to be mitigated prior to Final Inspection.
COT - RSBU - Masonry Pregrout  Partial Pass 7-6-23: Top out in back. Partial to allow rescheduling for carport wall extension.
08/28/2023 COT - RSBU - Masonry Pregrout  Passed 8/28/23 okay to grout final lift for carport wall extension