Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Masonry Pregrout
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/28/2023 | COT - RSBU - Masonry Pregrout | Partial Pass | 6-28-23: First lift. Note: Existing bedroom window compliant with emergency escape and rescue requirements of the IRC has been closed up per plan; side window will now need to be modified to comply with emergency escape and rescue opening requirements of IRC. Homeowner notified today. Front attached porch has combustible construction within 3 feet of property line, not shown on plans; will need to be mitigated prior to Final Inspection. |
|
| COT - RSBU - Masonry Pregrout | Partial Pass | 7-6-23: Top out in back. Partial to allow rescheduling for carport wall extension. | ||
| 08/28/2023 | COT - RSBU - Masonry Pregrout | Passed | 8/28/23 okay to grout final lift for carport wall extension |