Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address NEW:
2362 E COCHISE VISTA
Apply Date:
09/23/2022
Applicant:
Description:
REV_1, Electrical; R-Replace Carport with Sleeping Quarters

Permit Reviews

Permit Number - T22CM07347
Permit Status: Issued
Permit Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
Start Date Submittal Complete Date Status  
09/29/2023 RESIDENTIAL NEW DWELLING v.3 10/19/2023 APPROVED Review Details
12/19/2022 RESIDENTIAL NEW DWELLING v.1 01/20/2023 REQUIRES RESUBMIT Review Details
08/10/2023 RESIDENTIAL NEW DWELLING v.2 08/16/2023 REQUIRES RESUBMIT Review Details
10/03/2025 RESIDENTIAL NEW DWELLING v.2 11/18/2025 APPROVED Review Details
08/22/2025 RESIDENTIAL NEW DWELLING v.1 09/24/2025 REQUIRES RESUBMIT Review Details
10/19/2023 RESTAMP - RESIDENTIAL v.1 10/25/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - T22CM07347
Permit Status: Issued
Permit Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
Total Outstanding Activity Conditions - 1
Date Name
01/20/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - T22CM07347
Permit Status: Issued
Permit Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
Date Description Comments
10/21/2025 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
10/25/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Issued
Permit Number: T22CM07347
Permite Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
06/26/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 5/26/24: some of the previous corrections requested still not made. Exterior beams 4x8, window headers, anchor bolts, hold downs not nailed. Sewer lines need green tracer wire before covering. Stopped inspection
06/26/2024 BULD - Electrical Clearance N/A Re-inspection required 6/26/24: not ready missing panel, and ufer.
09/25/2026 COT - RSPL - Plumbing Final N/A Re-inspection required 9/25/26: label panel, insulate hose bib, paint or seal all exterior wood, add insulation to hot copper line at water heater, water heater requires an enclosure. A ladder to access roof is required. I did not inspect anything on the inside of home. Stopped inspection-additional items may be noted.
10/28/2026 COT - BULD - SWG Clearance N/A Not Applicable
10/28/2026 COT - RSEL - Electrical Final N/A Re-inspection required 10/28/2026
All corrections made. Pending change 15A and 20A breakers in kitchen, living room, bedroom, smoke detector and lights to be AFCI. Kitchen countertops needs to GFCI and receptacle below sink. Add pipe to temperature and pressure relief valve down with an air gap to ground.
10/28/2026 RSBU - Building Final N/A Re-inspection required 10/28/2026
All corrections made. Walked rest of unit. Pending change 15A and 20A breakers in kitchen, living room, bedroom, smoke detector and lights to be AFCI. Kitchen countertops needs to GFCI and receptacle below sink. Add pipe to temperature and pressure relief valve down with an air gap to ground. Add engineer letter stating truss design not required per approved plan.

Completed Inspections

Permit Status: Issued
Permit Number: T22CM07347
Permit Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
Total Completed Inspections - 10
Date Description Inspector Results Comments
07/09/2024 COT - RSPL - Rough Soil Passed 7/9/24: plumbing underground under pressure. Revision required a for laundry prior to final ok to backfill. Shading required
06/24/2025 COT - RSBU - Roof Nailing Passed 6/24/25
All corrections have been made.
06/24/2025 COT - RSBU - Preslab Passed
06/24/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 6/24/25
All corrections have been made.
06/24/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
07/01/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Passed 7/1/25
07/15/2026 BULD - Electrical Clearance Passed 07/15/2026
Clearance TEP ECO.
10/28/2026 COT - RSEL - Electrical Underground Passed 10/28/2026
All corrections made.
10/28/2026 COT - RSME - Mechanical Final Passed 10/28/2026
All corrections made.
10/28/2026 COT - RSEL - Outdoor Lighting Passed 10/28/2026
All corrections made.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-2_REV1_PLANS_SANCHEZ RESIDENCE_V2.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
OWNER-BUILD AFFIDAVIT_V1.PDF DOCUMENTS VIEW
CONS-4_PLANS_SANCHEZ RESIDENCE_V3.PDF DOCUMENTS VIEW
APPROVED DDO_V1.PDF DOCUMENTS VIEW
DDO_23_67_DECISION.PDF SPECIAL APPLICATIONS VIEW
DDO_23_67_NOTICE.PDF SPECIAL APPLICATIONS VIEW
DDO_23_67_APPLICATION.PDF SPECIAL APPLICATIONS VIEW
DDO_23_67_PLAN SET.PDF SPECIAL APPLICATIONS VIEW