Permit: T22CM07347
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
2362 E COCHISE VISTA
Address NEW:
2362 E COCHISE VISTA
Apply Date:
09/23/2022
Applicant:
Description:
REV_1, Electrical; R-Replace Carport with Sleeping Quarters
Permit Reviews
Permit Number - T22CM07347
Permit Status: Issued
Permit Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/29/2023 | RESIDENTIAL NEW DWELLING v.3 | 10/19/2023 | APPROVED |
| 12/19/2022 | RESIDENTIAL NEW DWELLING v.1 | 01/20/2023 | REQUIRES RESUBMIT |
| 08/10/2023 | RESIDENTIAL NEW DWELLING v.2 | 08/16/2023 | REQUIRES RESUBMIT |
| 10/03/2025 | RESIDENTIAL NEW DWELLING v.2 | 11/18/2025 | APPROVED |
| 08/22/2025 | RESIDENTIAL NEW DWELLING v.1 | 09/24/2025 | REQUIRES RESUBMIT |
| 10/19/2023 | RESTAMP - RESIDENTIAL v.1 | 10/25/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - T22CM07347
Permit Status: Issued
Permit Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/20/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - T22CM07347
Permit Status: Issued
Permit Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
| Date | Description | Comments |
|---|---|---|
| 10/21/2025 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 | |
| 10/25/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T22CM07347
Permite Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 5/26/24: some of the previous corrections requested still not made. Exterior beams 4x8, window headers, anchor bolts, hold downs not nailed. Sewer lines need green tracer wire before covering. Stopped inspection |
| 06/26/2024 | BULD - Electrical Clearance | N/A | Re-inspection required | 6/26/24: not ready missing panel, and ufer. |
| 09/25/2026 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 9/25/26: label panel, insulate hose bib, paint or seal all exterior wood, add insulation to hot copper line at water heater, water heater requires an enclosure. A ladder to access roof is required. I did not inspect anything on the inside of home. Stopped inspection-additional items may be noted. |
| 10/28/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 10/28/2026 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 10/28/2026 All corrections made. Pending change 15A and 20A breakers in kitchen, living room, bedroom, smoke detector and lights to be AFCI. Kitchen countertops needs to GFCI and receptacle below sink. Add pipe to temperature and pressure relief valve down with an air gap to ground. |
| 10/28/2026 | RSBU - Building Final | N/A | Re-inspection required | 10/28/2026 All corrections made. Walked rest of unit. Pending change 15A and 20A breakers in kitchen, living room, bedroom, smoke detector and lights to be AFCI. Kitchen countertops needs to GFCI and receptacle below sink. Add pipe to temperature and pressure relief valve down with an air gap to ground. Add engineer letter stating truss design not required per approved plan. |
Completed Inspections
Permit Status: Issued
Permit Number: T22CM07347
Permit Description: REV_1, Electrical; R-Replace Carport with Sleeping Quarters
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/09/2024 | COT - RSPL - Rough Soil | Passed | 7/9/24: plumbing underground under pressure. Revision required a for laundry prior to final ok to backfill. Shading required | |
| 06/24/2025 | COT - RSBU - Roof Nailing | Passed | 6/24/25 All corrections have been made. |
|
| 06/24/2025 | COT - RSBU - Preslab | Passed | ||
| 06/24/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 6/24/25 All corrections have been made. |
|
| 06/24/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 07/01/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Passed 7/1/25 | |
| 07/15/2026 | BULD - Electrical Clearance | Passed | 07/15/2026 Clearance TEP ECO. |
|
| 10/28/2026 | COT - RSEL - Electrical Underground | Passed | 10/28/2026 All corrections made. |
|
| 10/28/2026 | COT - RSME - Mechanical Final | Passed | 10/28/2026 All corrections made. |
|
| 10/28/2026 | COT - RSEL - Outdoor Lighting | Passed | 10/28/2026 All corrections made. |