Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM07347
Parcel: 132111770

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - T22CM07347
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/22/2025 Site Engineering - Standard NOT REQUIRED
09/24/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
09/18/2025 Residential Building - Standard REQUIRES RESUBMIT T22CM07347
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings.

Clarify if the proposed revision is for an addition to the primary dwelling (detached sleeping quarters) or a new dwelling with address for electrical service. The permit was started as an addition. Adding an electrical service requires a Pima County address if the Zoning section can approve the request. A dwelling unit with address may require imposing an impact fee. Check with the Zoning section for guidance.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

SITE PLAN:

1. The approved permit plans do not include an attached porch roof between the sleeping quarters and project south property line. Clarify if this request for revision includes the porch roof.

PLANS:

1. Roof projections may extend into the 3-foot fire separation distance line between dwelling units without fire spread control. Show the roof structure with one-hour fire-resistive wall construction parallel with the adjoining (neighboring) property line in compliance with IBC Table 721.1(2) or provide a clear 3’ fire separation distance between the property line and the structure.

SECTIONS - DETAILS:

1. Show one-hour fire-resistive construction parallel with the property line in compliance with IBC Table 721.1(2) extending from ground to roof and from end to end of the roof.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
09/24/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Claire Leighou, Planner

PROJECT: T22CM07347

2362 E Cochise Vista

Replace carport with sleeping quarters (2nd Review)

TRANSMITTAL DATE: 9/24/25



Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8.4) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Refer to building safety comments. Clarify if the proposed revision is for a detached sleeping quarters or for a new dwelling (ADU) with address for electrical service.



The site plan shows a porch addition that was not on the previously approved plans. Note this in your revision letter on the next submittal. The porch addition along the southeast property line does not meet the minimum setback requirement of 6’ or 2/3 the height of the exterior building wall, whichever is greater (UDC Table 6.3-2.A).

(a) If the proposed project remains a detached sleeping quarters, then a neighbor waiver is required for approval of the reduced setback. See Comment 4 below for information on the neighbor waiver. (b) If the proposed project is an ADU, then a Design Development Option (DDO) will be required for approval of the reduced setback. Contact Georgia Pennington at georgia.pennington@tucsonaz.gov for more information about the DDO process and an application.

The address is incorrect on the plan set; change North to East.

Based on aerial images, there is a shed along the southeast property line that appeared sometime around 2022. If it will remain, please add to the site plan and provide dimensions and perimeter yard setbacks. Add square footage to the lot coverage calculations.

The shed appears to not meet the minimum setback requirement of 6’ or 2/3 the height of the exterior building wall, whichever is greater (UDC Table 6.3-2.A), from the property line, which would require a neighbor waiver to be compliant. Per UDC Article 6.6.2.D, an accessory structure that is detached from a principal structure shall comply with the setback standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s) (2712 S Norton Vista).

My name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _______________________Date: ___________________________



The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code



If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you!
08/22/2025 PDSD Application Completeness Express REVIEW COMPLETED